6
GW-GNET+
Page 100
gas-lab
Q1
5. Go through all modules in this way until all adjustments meet your
requirements.
6. Select
File
– Save
as
and enter the name under which the parameter data
record shall be saved in GAS-WORKS. Close GW-GNET+, for instance via
File
– Exit
.
7. The parameter data record is now in the worksheet of GW-BASE. Before
exporting it to the device, you have to drag it into a suitable hierarchy of the
GAS-WORKS data management
12
.
8. Connect the DSS data interface at the device to a COM interface of the
computer using a parameterisation cable.
9.
Turn the calibration switch at the device to “open”.
10. Mark the parameter data record and select the
Data
– Export
menu item
from the main or context menu of GAS-WORKS.
11. The communication program starts.
The window appearing on your screen shows the information
Data
transmission to
gas-net
device
.
As soon as the transmission has been completed, the device will be re-
started. The message
Data transmission to
gas-net
device
in the
communication window disappears. The type plate of the connected
gas-
net
device is indicated instead, stating the most important device data.
Close the communication program now.
12
To drag a data record from the worksheet into a hierarchy, proceed as described below:
1. Mark the target hierarchy (which must possibly be created before).
2. Drag the data record with the mouse from the worksheet into the right half of the
configuration window.
Alternatively, drag the data record directly to a folder in the hierarchy (on the left side of
the configuration window).
Please refer to the GW-