Mounting
9
© Gardner Denver Deutschland GmbH
35
/
60
09.2013 · 610.44495.40.310
Fitting on the ventilation side
▪
Fill the new radial shaft seal ring 100% with grease.
▪
Apply
grease
to the entire surface of the sealing lip of the radial shaft seal ring
(452) using a brush.
▪
NOTICE! Note the installation position of the radial shaft seal ring (452)!
▪
Press the radial shaft seal (452) into the end plate (450).
▪
Apply
grease
to the entire surface on both sides of the spring washer (467).
▪
Place the spring washer (467) in the end plate (450).
▪
Apply
sealant
Epple 03213 to the ventilation side sealing surface of the motor
housing (001).
▪
Insert the nuts (459) into the ventilation side pockets in the motor housing
(001).
▪
Position the end plate (450) on the motor housing (001).
▪
Align the holes of the end plate (450) and motor housing (001).
▪
Secure the end plate (450) to the motor housing (001) using the screws (451).
▪
Hang the lifting device into the lifting eyes of the motor housing (001).
▪
Lift the motor housing (001) and insert into the assembly device (A) with the
ventilator side facing down.
▪
If necessary, secure against slipping and tipping.
▪
Remove the lifting device.
9.1
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
Tel. 071 918 60 60, Mail: [email protected]