Disassembly
8
© Gardner Denver Deutschland GmbH
33
/
60
09.2013 · 610.44495.40.310
Disassembly on the ventilation side
▪
Hang the lifting device into the lifting eyes of the motor housing (001).
▪
Lift the motor housing (001) out of the assembly device (A).
▪
Place the motor housing (001) down horizontally.
▪
Remove the lifting device.
▪
Remove the screws (451).
▪
Remove the nuts (459) from the pockets in the motor housing (001).
▪
Pull the end plate (450) off the motor housing (001) and remove.
Use two slotted screwdrivers to remove it if necessary.
▪
Remove the spring washer (467) from end plate (450).
▪
Remove the radial shaft seal (452) from the end plate (450) and note the instal-
lation position.
8.9
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
Tel. 071 918 60 60, Mail: [email protected]