Disassembly options
10
© Gardner Denver Deutschland GmbH
47
/
60
09.2013 · 610.44495.40.310
Disassembling the integrated frequency inverter 3FC4..2-
1ST/PB/CB/SC
▪
Remove the screw of the frequency inverter cover (600S) and remove along
with the toothed washer (600W).
▪
Remove the frequency inverter cover (600C).
▪
Mark the cables, if required, for assembling.
▪
Disconnect all the electrical connections to the frequency inverter (600).
▪
Remove the screws (638).
▪
Lift the frequency inverter (600) upwards.
▪
Remove the screws (637).
▪
Remove the hood (600D) and seal (600G).
▪
Mark the cables, if required, for assembling.
▪
Disconnect all electrical connections from the terminal board (650).
▪
Remove the screw (651).
▪
Remove the terminal board (650) by lifting it up.
▪
Remove the screws (642).
▪
Remove the adapter plate (648).
▪
Remove the seal (643).
10.2
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
Tel. 071 918 60 60, Mail: [email protected]