10
Disassembly options
610.44495.40.310 · 09.2013
50
/
60
© Gardner Denver Deutschland GmbH
Disassembling the cover side silencer and blind flange
▪
Remove the hexagon cap nuts (476).
▪
Remove the hexagon cap nuts (476) with threaded rods (444).
▪
Remove the silencer kit (990).
▪
Remove the flange (446).
▪
Removing the protective grid (445) and clean if necessary.
▪
Remove the dowel pin (443) from the silencer housing (403) or flange (446).
▪
Remove the silencer insert (413) from the silencer housing (403).
▪
Remove the screws (152) and remove the blind flange (035).
▪
Check the warning sign (5060) for damages and replace if required.
If the G-BH2 is equipped with standard silencers, then continue disassem-
bly with Disassembly of the silencer [
➙
25].
If the G-BH2 is equipped with standard ventilator, then continue disassem-
bly with Dismantle the ventilator [
➙
26].
If the G-BH2 is provided with an auxiliary ventilator (B), then continue disas-
sembly as per Disassembling the auxiliary ventilator [
➙
52].
10.4
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
Tel. 071 918 60 60, Mail: [email protected]