Disassembly
8
© Gardner Denver Deutschland GmbH
27
/
60
09.2013 · 610.44495.40.310
Disassembly of the compressor cover
▪
Screw the eye bolts into the holes for the cover position of the compressor
cover (030).
▪
Fix the lifting gear onto the eye bolts.
▪
G-BH2 carefully lift and move to a vertical axis position.
▪
Insert the G-BH2 with the ventilation side into the assembly device (A). The
shaft end of the rotor (005) must not lay-on.
▪
If necessary, secure against tipping.
▪
Remove the eye bolts.
▪
Mark the alignment of the compressor cover (030), compressor housing (002)
and motor housing (001) before disassembly for assembling correctly later.
▪
Remove the screws (014).
▪
Remove the screws (074).
▪
Carefully loosen the compressor cover (030) using a flat-bladed screwdriver
and remove it.
8.3
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
Tel. 071 918 60 60, Mail: [email protected]