11
Assembly options
610.44495.40.310 · 09.2013
54
/
60
© Gardner Denver Deutschland GmbH
Assembly of cover side silencer and blind flange
▪
Put
medium strength threadlocker
onto the hexagon cap nuts (476).
▪
Screw the hexagon cap nuts (476) onto the threaded rods (444).
▪
Insert threaded pins (444) into the silencer kit (990).
▪
Position the silencers (item 990) on the compressor cover (item 030) and
mount it using threaded pin (item 444) and hexagon cap nuts (item 476).
NOTICE! Note the position of the adhesive label for the direction of deliv-
ery (5170) on the silencer housing. While changing the silencer housing
(403) stick the adhesive label of the direction of delivery (5170) on accord-
ing to the adjacent figure.
▪
Position the blind flange (035) with a legible warning sign (5060) and fit using
the screws (152).
If the G-BH2 is equipped with standard silencers, then continue assembly
with Fitting the silencer [
➙
44].
If the G-BH2 is equipped with integrated frequency inverter 2FC4..2-
1ST/PB/CB/SC (A), then continue assembly with Assembly of integrated
frequency inverter 2FC4..2-1ST/PB/CB/SC [
➙
56].
If the G-BH2 is equipped with integrated frequency inverter 2FC4..3-
1ST/PB/CB/SC (A), then continue assembly with Assembly of integrated
frequency inverter 2FC4..3-1ST/PB/CB/SC [
➙
57].
If the G-BH2 is equipped with integrated frequency inverter 2FC4...-1NE (A),
then continue assembly with Assembly of the integrated frequency inverter
- 2FC4...-1NE [
➙
58].
Complete the assembly using Testing [
➙
59].
11.2
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch