10
Disassembly options
610.44495.40.310 · 09.2013
52
/
60
© Gardner Denver Deutschland GmbH
Disassembling the auxiliary ventilator
▪
Mark the installation position of the auxiliary ventilator (501) for assembling.
▪
Remove the auxiliary ventilator screws (504).
▪
Remove the auxiliary ventilator (501).
▪
Remove the screws (503) and washers (502).
▪
Remove the ring for auxiliary ventilator (500).
Continue disassembly with Disassembly of the compressor cover [
➙
27].