8
Disassembly
610.44495.40.310 · 09.2013
26
/
60
© Gardner Denver Deutschland GmbH
Dismantle the ventilator
If the G-BH2 is provided with an auxiliary ventilator (B), then continue disas-
sembly as per Disassembling the auxiliary ventilator [
➙
52].
▪
Remove the fan guard screws (503).
▪
Remove the fan guard (500).
▪
Remove the circlip of the auxiliary ventilator (506) if available using circlip pli-
ers.
▪
Pull the external fan (501) off, use two slotted screwdrivers to prise it off if
necessary.
▪
Remove the feather key (505) if available using pliers.