Assembly options
11
© Gardner Denver Deutschland GmbH
57
/
60
09.2013 · 610.44495.40.310
Assembly of integrated frequency inverter 2FC4..3-
1ST/PB/CB/SC
▪
Insert the gasket (643) into the adapter plate (648).
▪
Place the adapter plate (648) on the terminal box opening of the motor hous-
ing (001) with an overhang on the ventilation side.
▪
Insert the screws (642) into the holes of the adapter plate (648) and screw
them to the terminal box in the motor housing (001).
M
A
=
4.2 – 5.0 Nm
(3.10 – 3.70 ft lbs)
▪
Position the terminal board (650) on the adapter plate (648).
▪
Secure the terminal board (650) and the adapter plate (648) using the screw
(651).
M
A
=
4.2 – 5.0 Nm
(3.10 – 3.70 ft lbs)
▪
Wire all electrical connections to the terminal board (650) according to the
marks or the circuit diagram.
▪
Insert the gasket (600G) into the hood (600D).
▪
Position the hood (600D) on the adapter plate (648).
▪
Screw the hood (600D) and the adapter plate (648) using screws (637).
M
A
=
7.5 – 9.0 Nm
( 5.55– 6.65 ft lbs)
▪
Plug the frequency inverter (600) into the hood (600D) from above with over-
hang on the ventilation side.
▪
Screw the frequency inverter (600) and the hood (600D) using screws (638).
M
A
=
18 – 22 Nm
(13.3 – 16.2 ft lbs)
▪
Wire all electrical connections to the frequency inverter (600) according to the
marks or the circuit diagram.
▪
Position the frequency inverter cover (600C) on the frequency inverter (600).
▪
Plug the toothed washer (600W) onto the screw (600S).
▪
Screw the frequency inverter cover (600C) and frequency inverter (600) in us-
ing screws (600S).
Complete the assembly using Testing [
➙
59].
11.5
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch