55/112
WL31/WL31TG
8.4 READ MEMORY [20]
Menu > Event memory > Read memory
Authorization level:
MASTER
,
TECHNICIAN
How to do it
:
1. Press the
OK
key to access the last registered event and use the
and
keys to scroll up and down the
list of the registered events.
2. Press the
OK
key many times to read the detailed information relating to an event.
3. Use the
and
keys to go back to the events list.
8.5 CANCEL MEMORY [21]
Menu > Event memory > Cancel memory
Authorization level:
TECHNICIAN
This enables you to delete from the WL31 control panel all the registered events.
How to do it
:
1. Press the
OK
key and use the
and
keys to choose between «Confirm YES» (cancel) and «Confirm
NO» (do not cancel).
2. Confirm your choice by pressing the
OK
key.
Warning! The deleting operation can not be reversed.
HOW TO READ THE EVENT MEMORY
When the event memory is entered, it shows a series of detailed information on the registered event.
The symbols
●
and
○
shows the beginning and the end of each event, for example:
SETTING
8.6 SETTING [3]
Menu > Setting
Authorization:
MASTER
,
TECHNICIAN
,
USER
Sub-menu
Fast code
Setting - Exclude / Include
30
Setting - Time and date
31
Setting - Language
32
Setting - Change code
33
Setting - Users
34
Setting - Control delay
35
Setting - Advanced
36
For TECHNICIAN CODE only
●001 11:49 07/02
VALID CODE
SOURCE
M -MASTER
●002 11:30 07/02
TAMPER
CONTROL UNIT
SABOTAGE
○003 12:01 07/02
TAMPER
CONTROL UNIT
SABOTAGE
●004 06:10 07/02
SECTORS
TOTAL ACTIVATION
SETT 1- [NAME]
SOURCE:
CONTROL UNIT
Total activation
(●) sector 1
Tamper event end (○)
Tamper event beginning (●)
Inputing of a valid code