34/112
WL31/WL31TG
4.3 CONTROL PANEL INSTALLATION
4.3.1 INSTALLATION WARNING
To install the control panel correctly please take the following precautions:
Do not install the control panel on metallic surfaces or near big metallic objects.
Do not install the control panel near electromagnetic sources such as electric engines, reactors, electric panels,
etc.
If possible, do not install the control panel on reinforced concrete or solid brick walls.
Install the control panel at a height of approximately 160 cm from the floor (eyes must be at the same level with
the display).
Install the control panel in a position which is central to the different devices.
Install the control panel in a protected area away from passages.
Verify that in the chosen location it is possible to carry out the connections with the
PSTN or GSM telephone lines and
to the electric network
. Even if there is no immediate need, always verify this in anticipation of future developments.
4.3.2 INSTALLATION
Fix the control panel on a flat wall with nogs using the three holes positioned on the back of the control panel itself.
For possible connections to the electric network and to PSTN telephone network use the specific cable routes at
the wire Inputs and outputs.
Warning
: before connecting the control panel power pack switch the electric system power off.
Hole for wall fixing
Hole for wall fixing
Hole for wall fixing
Wires passages
Fastening columns
for 3