Base must be level and front of cabinet square for proper
operation.
•
Grounded outlet should NOT be located in shaded area,
as indicated.
Combination Installations
For installation details refer to Project Planning Section.
•
Microwave can NOT be installed above any gas wall oven.
•
Microwave can be built in alone or is approved to be used
in combination with any Electrolux ICON
®
Electric Single
Wall Oven and / or Warmer Drawer.
(Refer to model-
specific Combination Installation Specifications pages.)
•
When used in combination with another Electrolux ICON
®
built-in product, a minimum clearance of 3-1/8" required
from bottom of Built-In Microwave cutout to top edge
of companion product’s faceplate, leaving a 2" visible gap
between both product faceplates.
Installation Specifications
•
Product Weight – 60 Lbs.
•
Voltage Rating – 120V / 60 Hz / 15 Amps
•
Connected Load (kW Rating) @ 120 Volts = 1.55 kW
(For use on adequately wired 120V, dedicated circuit
having 2-wire service with a separate ground wire.
Appliance must be grounded for safe operation.)
•
Amps @ 120 Volts = 13 Amps
•
Always consult local and national electric codes.
•
Allow 19" minimum clearance for 90° door swing.
•
Built-In installation requires use of 30" Trim Kit
(E30MO65TMK) which is supplied and includes Stainless
Steel Faceplate, Exhaust Duct Assembly and Bottom
Duct Assembly – shipped in separate box.
•
Minimum 20-1/8" deep oven cutout dimension is critical
for proper installation for oven and faceplate to fit flush
against cabinet front.
•
Full base of solid plywood or similar material required,
capable of supporting 100 Lbs.
planning
information
For model:
E30MO65GSS
Note:
For planning
purposes only. Refer
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
to change.
Built-In Microwave
E30MO65GSS
30"min.
20
1
/
8
"
min.
19
7
/
8
"
min.
20
3
/
8
"
max.
Full plywood
base required
to support
100 lbs.
2"
min.
26
1
/
2
"min.
27"max.
2"
(visible
gap)*
30"
Allow at least
19" clearance for door
depth when open
21
23
/
32
"
24
5
/
8
"
20
29
/
32
"
Power
cord
location
(right
bottom
rear)
Exhaust Duct
Assembly
Faceplate
19
5
/
8
"
Bottom Duct Assembly
7
/
8
"
Bottom Duct Assembly
120V/60Hz
grounded outlet
Outlet should
NOT be located
within shaded
area
26
1
/
2
"
20
1
/
8
" min.
19
7
/
8
"
5"
11
1
/
2
"
*
Note:
When used in combination with
another Electrolux ICON
®
built-in product, a
minimum clearance of 3
1
/
8
" required from
bottom of Built-In Microwave cutout to top
edge of companion product’s faceplate,
leaving a 2"visible gap between both
product faceplates
Built-In Convection Microwave
Summary of Contents for ICON Professional E30DF74GPS