51
electroluxicon.com
Electric Cooktop
E36EC70FSS
5"
21
1
/
2
"
36
3
/
4
"
13"
max.
cabinet
depth
18"
min.
30" min. for
unprotected cabinet
24" min. for
protected surface
36
3
/
4
"
5" min.
25"min.
7
1
/
2
" min. to nearest
combustible wall
(either side of unit)
24"
1
1
/
2
" min. recommended
distance between rear
edge of cutout and
nearest combustible
surface above countertop
2
1
/
2
" min. from edge of cutout
to front edge of countertop
20
1
/
8
" min.
20
1
/
4
" max.
10"
12"
35
7
/
8
"min.
36"max.
Approximate location
of junction box
4"x 8" opening to route
armored cable
Electric Cooktops
planning
information
For 36" model:
E36EC70FSS
Note:
For planning
purposes only. Refer
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
to change.
•
Allow 1-1/2" minimum clearance between rear edge
of cutout and nearest combustible surface above
countertop.
•
Allow 7-1/2" minimum clearance from edge of cooktop
to nearest combustible wall on either side of unit.
•
Drawers not recommended beneath cooktop.
•
To reduce risk of fire when using overhead cabinetry,
install vent hood that projects horizontally a recommended
minimum of 5" beyond bottom of cabinets.
Combination Installations
For installation details refer to Project Planning Section.
•
Cooktop model E36EC70FSS is approved to be used
over any Electrolux ICON
®
Single Wall Oven.
(Refer to
Electric Cooktop Installation Over 30" Electric Single Wall
Oven Specifications page.)
•
Cooktop model E36EC70FSS is approved to be used
in combination with an Electrolux ICON
®
36" Downdraft
Vent.
(Refer to Drop-In Cooktop / Downdraft Vent
Countertop Preparation page for detailed installation
specifications.)
Installation Specifications
•
Product Weight – 50 Lbs.
•
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208
Volt, 60 Hertz AC only electrical supply with ground
required on separate circuit fused on both sides of line.
•
Connected Load (kW Rating) @ 240 / 208 Volts
= 10.5 / 7.9 kW
•
Amps @ 240 / 208 Volts = 44.0 / 38.0 Amps
•
Recommended Circuit Breaker – 50 Amps
•
Always consult local and national electric codes.
•
Allow 2" space below armored cable opening to clear
electrical cable and allow space for installation of junction
box on wall at back of cooktop.
•
Overhead cabinetry should not exceed a 13" max. depth.
•
Allow 30" minimum clearance between top of cooktop
and bottom of unprotected wood or metal overhead
cabinetry.
•
Absolute minimum horizontal distance between overhead
cabinets installed to either side of appliance must be
no less than maximum width of appliance.
•
Allow 24" minimum clearance when bottom of wood or
metal overhead cabinet is protected by not less than
1/8" flame-retardant millboard covered with not less than
No. 28 MGS sheet steel, 0.015" stainless steel, 0.024"
aluminum or 0.020" copper.
Optional
Accessories
Granite Countertop
Installation Kit
PN # 903061-9010