Installation Specifications
•
Product Weight – 240 Lbs.
•
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208
Volt, 60 Hertz AC only electrical supply with ground
required on separate circuit fused on both sides of line.
•
Connected Load (kW Rating) @ 240 / 208 Volts =
7.1 / 6.1 kW
•
Amps @ 240 / 208 Volts = 30 / 30 Amps
•
Recommended Circuit Breaker – 40 Amps
•
Always consult local and national electric codes.
•
Minimum 23-1/4" clearance for oven door depth
when open.
•
Suggested distance from floor is 11-1/2". Minimum
required distance is 4-1/2".
•
Minimum 24" deep cutout dimension is critical for proper
installation, to ensure that oven’s faceplate will fit flush
against cabinet front.
•
Full oven base of solid plywood or similar material
required, capable of supporting 300 Lbs.
•
Base must be level and cabinet front must be square.
•
Microwave Combination Oven is NOT approved to be
used in stackable or side-by-side installation.
planning
information
For models:
E30MC75JPS
E30MC75JSS
Note:
For planning
purposes only. Refer
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
to change.
Installation drawing shown
with professional series model.
Power
supply
location
(left
bottom
rear)
45
1
/
4
"
46
5
/
8
"
24
5
/
8
"
30"
7
/
8
"
Allow at least
23
1
/
4
" clearance
for door depth
when open
28
1
/
4
"
Spacer
3" max.
Electrical
junction
box location
4" x 4"
opening
to route
armored
cable
2
1
/
2
"
min.
11
1
/
2
"
suggested
distance
4
1
/
2
"
min.
required
45
3
/
8
"
min.
46"
max.
Full base
required
to support
300 lbs.
28
1
/
2
"min.
29"max.
24" min.*
(critical
dimension)
2" min.
*Critical dimension –
MUST be applied
Bottom cutout
edge must be
finish cut
30"min.