95
electroluxicon.com
Installation Specifications
•
Voltage Rating – 120V / 60 Hz / 15 Amps
•
Connected Load (kW Rating) @ 120 Volts = 1.0 kW
(For use on adequately wired 120V, dedicated circuit
having 2-wire service with a separate ground wire.
Appliance must be grounded for safe operation.)
•
Amps @ 120 Volts = 8.0 Amps
•
Do not use same circuit as cooktop.
•
Always consult local and national electric codes.
Check local building codes for installation requirements,
as they may vary per locale.
•
Vent must be installed in vertical orientation only.
•
Vent unit outside of building only.
•
Exhaust Duct Required – 3-1/4" x 10"
(3-1/4" x 10" to
round transition duct will be needed)
•
Do not use flexible duct. Round duct instead of rectangular
duct recommended, especially when elbows are required.
•
When multiple elbows are necessary, ensure a minimum
of 24" of straight duct between any two elbows.
•
Thermal breaks such as short section of nonmetallic duct,
should be used in areas of extreme cold.
•
For most efficient airflow exhaust, use a straight run or
as few elbows as possible.
•
Cold weather installations should have additional backdraft
damper installed.
Remote Exhaust Blower
•
1,600 CFM Remote Exhaust Blower (PN # 5304444802)
included with vent – shipped in separate box.
•
Installation Options – roof or exterior wall mount for
against-wall vent installation and under-floor mount for
island vent installation.
Combination Installations
For installation details refer to Project Planning Section.
•
Installing a Downdraft Vent in combination with any gas
cooking surface will affect optimum burner efficiency.
•
Downdraft Vents can NOT be used in combination with
any cooktop backsplash.
•
Downdraft Vent model E30DD75ESS is approved to
be used in combination with Electrolux ICON
®
Cooktop
models E30EC65ESS, E30EC70FSS, E30IC75FSS,
E30IC80ISS, E30GC64ESS, E30GC70FSS and
E30GC74GPS.
(For detailed countertop preparation,
refer to Drop-In and Slide-In Cooktop / Downdraft Vent
Countertop Preparation pages.)
•
Proper combination installation of Electrolux ICON
®
Downdraft Vent model E30DD75ESS and approved
30" Gas Slide-In Cooktop will require cooktop power cord
to be relocated to underside of unit.
(For details, refer to
30" & 36" Gas Slide-In Cooktop Power Cord Relocation
Instructions page or on the web at electroluxicon.com.)
planning
information
For 30" model:
E30DD75ESS
Note:
For planning
purposes only. Refer
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
to change.
Downdraft Vents
Downdraft Vent
E30DD75ESS
2
13
/
16
"
1
15
/
16
"
3"
Wallboard
Studwall
2
1
/
8
"
9
/
32
"
Cooktop/
Range
1
/
4
" min.
3
/
4
" max.
backsplash
thickness
Vent unit
Motor cover