31
electroluxicon.com
Gas and Electric Slide-In Cooktops
Optional
Accessories
9" Stainless
Steel Backsplash
PN # ACCBG09-48SI
Black Gas
Valve Knob
PN # 318313302
•
Allow 24" minimum clearance when bottom of wood or
metal overhead cabinet is protected by not less than
1/8" flame-retardant millboard covered with not less than
No. 28 MGS sheet steel, 0.015" stainless steel, 0.024"
aluminum or 0.020" copper.
•
Allow 2-1/2" minimum clearance between rear edge
of cooktop and nearest combustible surface above
countertop. If required clearance can not be maintained,
then optional stainless steel backsplash or noncombustible
backsplash material must be used – otherwise installation
will require custom cabinet and countertop dimensions.
•
Allow 10" minimum clearance from edge of cooktop to
nearest combustible wall on either side of unit.
•
Drawers not recommended beneath cooktop.
•
To reduce risk of fire when using overhead cabinetry,
install vent hood that projects horizontally a recommended
minimum of 5" beyond bottom of cabinets.
Combination Installations
•
Cooktop model E48GC76EPS is NOT approved to be
used over any Electrolux ICON
®
Single Wall Oven.
Installation Specifications
•
Product Weight – 190 Lbs.
•
Voltage Rating – 120V / 60 Hz / 15 Amps
•
Connected Load (kW Rating) @ 120 Volts = 0.03 kW
(For use on adequately wired 120V, dedicated circuit
having 2-wire service with a separate ground wire.
Appliance must be grounded for safe operation.)
•
Amps @ 120 Volts = 0.25 Amps
•
Always consult local and national electric and gas codes.
•
Cooktop ships with 3/4" factory regulator.
•
LP Gas conversion kit supplied.
•
Plan installation to access electrical connection, gas
shutoff valve, and pressure regulator from front of cabinet.
Locate 120V grounded outlet and gas supply in a
30" W x 15-1/2" H area on rear wall, 10" above floor and
6" to right from center of cooktop.
•
Overhead cabinetry should not exceed a 13" max. depth.
•
Allow 30" minimum clearance between top of cooktop
and bottom of unprotected wood or metal overhead
cabinetry.
•
Absolute minimum horizontal distance between overhead
cabinets installed to either side of appliance must be
no less than maximum width of appliance.
planning
information
For 48"
gas model:
E48GC76EPS
Note:
For planning
purposes only. Refer
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
to change.
1"min.
22"
3"
min.
25"
Support
platform
1
1
/
2
" typical
countertop
edge
10"min. to
nearest combustible wall
(either side of unit)
7
3
/
4
"
46"
48"
24"
Opening to
route gas and
electrical supply
48" min.
13"
max.
cabinet
depth
18"
min.
30" min. for
unprotected cabinet
24" min. for
protected surface
Side inset
5
/
8
"
7
3
/
4
"
Optional 9" stainless
steel backsplash
(attaches to wall)
48"
26
1
/
2
"
1
/
2
"
*If 2
1
/
2
" clearance can not be maintained, then optional
stainless steel backsplash or noncombustible backsplash
material must be used – otherwise this installation will
require custom cabinet and countertop dimensions
2
1
/
2
" min. required distance between rear
edge of cooktop and nearest combustible
surface above countertop*
Summary of Contents for ICON Professional E30DF74GPS
Page 1: ...design guide ...
Page 4: ...4 ...