65
electroluxicon.com
Built-In Microwave Oven w/Drop-Down Door
E30MO75HPS
21
11
/
16
"
Allow at least
15" clearance
for door depth
when open
22"
20
3
/
4
"
23
1
/
2
"
28"
30"
Power
supply
location
(left
bottom
rear)
Bottom Duct Assembly
CL
120V/60Hz
grounded outlet
Outlet should NOT
be located within
shaded area
20
1
/
8
"min.
28
1
/
2
"min.
29"max.
21"
min.
21
1
/
2
"
max.
Bottom Duct Assembly
4"
6"
18"
20
1
/
8
"
min.
21"
min.
21
1
/
2
"
max.
Full plywood
base required
to support
150 lbs.
2"
min.
28
1
/
2
"min.
29"max.
2"
(visible
gap)*
24"
min.
30
1
/
8
"
min.
36"min.
required
distance
to floor
*
Note:
When used in combination with
another Electrolux ICON
®
built-in product, a
minimum clearance of 2
1
/
8
" required from
bottom of Built-In Microwave cutout to top
edge of companion product’s faceplate,
leaving a 2"visible gap between both
product faceplates.
Combination Installations
For installation details refer to Project Planning Section.
•
Microwave is NOT approved to be used under counter.
•
Microwave can be built in alone or is approved to be used
in combination with any Electrolux ICON
®
Electric Single
Wall Oven and / or Warmer Drawer.
(Refer to model-
specific Combination Installation Specification pages.)
•
When used in combination with another Electrolux ICON
®
built-in product, a minimum clearance of 2-1/8" required
from bottom of Built-In Microwave cutout to top edge
of companion product’s faceplate, leaving a 2" visible gap
between both product faceplates.
Installation Specifications
•
Product Weight – 84 Lbs.
•
Voltage Rating – 120V / 60 Hz / 15 Amps
•
Connected Load (kW Rating) @ 120 Volts = 1.6 kW
(For use on adequately wired 120V, dedicated circuit
having 2-wire service with a separate ground wire.
Appliance must be grounded for safe operation.)
•
Amps @ 120 Volts = 13.7 Amps
•
Always consult local and national electric codes.
•
Minimum 15" clearance for oven door depth when open.
•
Minimum required distance from floor is 36".
•
Minimum 20-1/8" deep oven cutout dimension is critical
for proper installation for oven and faceplate to fit flush
against cabinet front.
•
Full oven base of solid plywood or similar material
required, capable of supporting 150 Lbs.
•
Base must be level and cabinet front must be square.
•
Grounded outlet should NOT be located in shaded area,
as indicated.
planning
information
For models:
E30MO75HPS
E30MO75HSS
Note:
For planning
purposes only. Refer
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
to change.
Installation drawing shown
with professional series model.
Built-In Microwaves with Drop-Down Door
Summary of Contents for ICON Professional E30DF74GPS
Page 1: ...design guide ...
Page 4: ...4 ...