102
refrigeration
Built-In All Freezer & All Refrigerator
Optional
Accessories
Single Louvered Trim Kit
TRIMKITSS1
For single unit installation.
Includes louvered top grille
and vented, louvered toe kick,
2-9/16" H leveling system
and side / top trim pieces.
Double Louvered Trim Kit
TRIMKITSS2
For double unit, side-by-
side installation. Includes
full-width, louvered top grille
and vented, louvered toe
kick, two 2-9/16" H leveling
systems, side / top trim pieces
and hardware to secure
side-by-side units together.
PureAdvantage
®
Air Filter Replacement
Cartridge
PN # EAFCBF
planning
information
For model:
E32AR75JPS
Note:
For planning
purposes only. Refer
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
to change.
•
Refrigerator must be placed on level surface of hard
material, same height as flooring. Surface must support
approximately 800 lbs. when fully loaded. Unit equipped
with 4-point leveling.
“Built-In Look” Specifications
•
Minimum opening of 72" H x 33" W x 25-1/4" D required
for single-unit “Built-In Look” installation; 66" W required
for double-unit installation. (72" H to be measured from
finished floor to underside of soffit or overhead cabinet.)
•
Remove all wall / floor molding prior to built-in installation.
Optional Trim Kit Specifications
•
If optional Single or Double Louvered Trim Kit is to be
used, different cutout dimensions are required. Kits can be
adapted to fit either 75" or 79" opening height. (
Refer to
cutout dimensions on this page and detailed Louvered Trim
Kit installation instructions included with kit or on web.
)
•
Remove all wall / floor molding prior to built-in installation.
Installation Specifications
•
Product Weight – 230 Lbs.
•
An electrical supply with grounded three-prong receptacle
is required. The power supply circuit must be installed
in accordance with current edition of
National Electrical
Code (NFPA 70)
and local codes & ordinances.
•
Voltage Rating – 120V / 60 Hz / 20 Amps
•
Connected Load (kW Rating) @ 115 Volts = 0.55 kW
•
Amps @ 115 Volts = 5 Amps
•
Always consult local and national electric codes.
•
Minimum 25-1/4" depth requires recessed electrical outlet.
•
To allow for ease of installation, tape excess power cord
to back of unit.
•
When installing refrigerator adjacent to wall, cabinet
or other appliance that extends beyond front edge of
unit, 20" minimum clearance recommended to allow for
optimum 140° door swing, providing complete drawer /
crisper access and removal.
(Absolute 4" min. clearance
will ONLY allow for 90° door swing which will provide
limited drawer / crisper access with restricted removal.)
All Refrigerator
E32AR75JPS
Summary of Contents for ICON Professional E30DF74GPS
Page 1: ...design guide ...
Page 4: ...4 ...