MANUAL ELDES ESIM264 V3.2
MANUAL ELDES ESIM264 V3.2
2.3. Wiring Diagrams
2.3.1. General Wiring
CO
M
BELL- BELL+
G
Y
C2
AU
X-
AU
X+
AC
/D
C
AC
/D
C
Z1 CO
M
Z2 Z3 CO
M
Z4
DA
TA
+5
V
M
IC
-
M
IC
+
BU
Z-
C1
BU
Z+
CO
M
CO
M
Z6
Z5
MIC
BUZ
SIREN/BELL
iButton®
key reader
Temperature sensor
EKB2
EKB3
EPGM1
Z1 Z2
Backup Battery
12V 1.3-7Ah
Metal cabinet
PE terminal
Relay
module
500mA max.
Z4
Z3
Z5 Z6
Fuse 500 mA
~230V 50Hz
~16-24V
AKU+
AKU-
5,6 kΩ
5,6 kΩ
5,6 kΩ
5,6 kΩ
5,6 kΩ
5,6 kΩ
2
2.3.2. Zone Connection Types
Type 1
Example of 4-wire smoke detector wiring
Z1
CO
M
AUX+
+Vin
GND
C1
COM
NO
5,6 kΩ
3
6-Zone mode: Nor-
mally open contact
with 5,6KΩ end-of-
line resistor.
Type 2
Example of magnetic door contact wiring
6-Zone mode: Nor-
mally closed contact
with 5,6KΩ end-of-
line resistor
COM
NC
Magnet
CO
M
Z1
5,6 kΩ
4
NOTE:
Based on the example given, in the event of an alarm, the smoke detector could be reset by turning OFF and ON the PGM output
C1. For more details, please refer to
18.4. Turning PGM Outputs ON and OFF.
NOTE:
The system does NOT support 2-wire smoke detectors.
Type 3
Example of motion detector wiring
Z1
CO
M
COM
AUX+
AU
X-
+Vin
GND
NC
TAMP
5,6 kΩ
3,3 kΩ
5
6-Zone mode: Tamper
and 5,6KΩ end-of-line
resistor and 3,3KΩ
end-of-line resistor
with normally closed
contact.
Type 4
Example of magnetic door contact (Z1) and glass break sensor (Z7) wiring
AUX+
+Vin
AU
X-
GND
COM
COM
NC
NC
CO
M
Z1
5,6 kΩ
3,3 kΩ
Magnet
6
ATZ mode: 5,6KΩ
end-of-line resistor
and normally closed
contact with 3,3KΩ
end-of-line resistor
and normally closed
contact
Type 5
Example of motion detector (Z1) and magnetic door contact (Z7) wiring
Z1
CO
M
COM
COM
AUX+
AU
X-
+Vin
GND
NC
NC
TAMP
5,6 kΩ
5,6 kΩ
3,3 kΩ
Magnet
ATZ mode: Tamper,
5,6KΩ end-of-line
resistor, 5,6KΩ end-
of-line resistor with
normally closed
contact and 3,3KΩ
end-of-line resistor
with normally closed
contact.
7
See also
14.3. 6-Zone Mode
and
14.4. ATZ (Advanced Technology Zone) Mode.