MANUAL ELDES ESIM264 V3.2
MANUAL ELDES ESIM264 V3.2
14.9. Disabling and Enabling Zones
By default, all zones, except keypad and virtual zones, are enabled. To permanently disable/enable an individual zone, please refer to the
following configuration methods.
Disable zone
SMS
SMS text message content:
ssss_Znn:OFF
Value:
ssss
– 4-digit SMS password;
nn
– zone number, range – [1... 44].
Example:
1111_Z13:OFF
EKB2
Menu path:
On-board zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
ONBOARD
ZONES
→
OK
→
ZONE 1... 12
→
OK
→
STATUS
→
OK
→
DISABLE
→
OK
Wireless zone:
OK
→
CONFIGURATION
→
STATUS
→
aaaa
→
OK
→
ZONES
→
OK
→
WIRELESS
ZONES
→
OK
→
WLESS ZONE 1... 16
→
OK
→
STATUS
→
OK
→
DISABLE
→
OK
Keypad zone: O
K
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
KEYPAD ZONES
→
OK
→
KEYPAD 1... 4 ZONE
→
OK
→
STATUS
→
DISABLE
→
OK
EPGM1 zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
EPGM1 ZONES
→
OK
→
EPGM1 ZONE 1... 16
→
OK
→
STATUS
→
DISABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 52, zone number and parameter status value:
52 nn 0 #
Value:
nn
– zone number, range – [01... 44].
Example:
52360#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
Enable zone
SMS
SMS text message content:
ssss_Znn:ON
Value:
ssss
– 4-digit SMS password;
nn
– zone number, range – [1... 44].
Example:
1111_Z6:ON
EKB2
Menu path:
On-board zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
ONBOARD
ZONES
→
OK
→
ZONE 1... 12
→
OK
→
STATUS
→
OK
→
ENABLE
→
OK
Wireless zone:
OK
→
CONFIGURATION
→
STATUS
→
aaaa
→
OK
→
ZONES
→
OK
→
WIRELESS
ZONES
→
OK
→
WLESS ZONE 1... 16
→
OK
→
STATUS
→
OK
→
DISABLE
→
OK
Keypad zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
KEYPAD ZONES
→
OK
→
KEYPAD 1... 4 ZONE
→
OK
→
STATUS
→
DISABLE
→
OK
EPGM1 zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
EPGM1 ZONES
→
EPGM1 ZONE 1... 16
→
OK
→
STATUS
→
DISABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 52, zone number and parameter status value:
52 nn 1 #
Value:
nn
– zone number, range – [01... 44].
Example:
52151#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
15. STAY MODE
Stay mode allows the user to arm and disarm the alarm system without leaving the secured area. If the zones with Stay attribute enabled
are violated when the system is Stay armed, no alarm will be caused. Typically, this feature is used when arming the system at home before
going to bed.
The system can be Stay armed under the following conditions:
• If a Delay-type zone is NOT violated during exit delay and a zone (-s) with Stay attribute enabled exists, the system will arm in Stay
mode. When arming the system in Stay mode under this condition, one of the available arming methods must be used that provide exit
delay. For more details on these methods, please refer to
13. EXIT AND ENTRY DELAY
.
• The system will instantly arm in Stay mode when using one of the following methods.
Arm the system in
Stay mode
EKB2
Menu path:
P2
→
uuuu
→
OK
Value:
uuuu
– 4-digit user code.
EKB3
Press the [STAY] key and enter user code:
STAY uuuu
Value:
uuuu
– 4-digit user code.
Example:
STAY1111
When the system is successfully armed in Stay mode, EKB2 keypad will display
STAY
message in the home screen view.
ATTENTION:
System arming in Stay mode by the keypad must be carried out without Configuration mode being activated.
NOTE:
The system can be armed in Stay mode, only if there is at least one zone with Stay attribute enabled.
NOTE:
Stay mode is not supported by virtual zones.
For more details on how to enable Stay attribute for zone, please refer to
14.6. Zone Attributes
.