MANUAL ELDES ESIM264 V3.2
MANUAL ELDES ESIM264 V3.2
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
Set user name
SMS
SMS text message content:
ssss_SETGPRS:USER:usr-name
Value:
ssss
– 4-digit SMS password;
usr-name
– up to 31 character user name provided by
the GSM operator.
Example:
1111_USER:mobileusr
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
Set password
SMS
SMS text message content:
ssss_SETGPRS:PSW:password
Value:
ssss
– 4-digit SMS password;
password
– up to 31 character password provided by
the GSM operator.
Example:
1111_SETGPRS:PSW:mobilepsw
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
By default, if the initial attempt to transmit data to the monitoring station via GPRS network method is unsuccessful, the system will make
up to 2 additional attempts. If all attempts are unsuccessful, the system will switch to next backup connection that follows in the sequence
and will attempt to transmit data until it is successfully delivered to the monitoring station.
Set attempts
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
MS SETTINGS
→
OK
→
GPRS SETTINGS
→
OK
→
GPRS ATTEMPTS
→
OK
→
att
→
OK
Value:
aaaa
– 4-digit administrator password;
att
– number of attempts, range – [1... 255].
EKB3
Enter parameter 68 and number of attempts:
68 att #
Value:
att
– number of attempts, range – [01... 255].
Example:
6809#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
To report the online status, the system periodically transmits (By default – every 180 seconds) Test Event data message (ping) to the
monitoring station via GPRS network.
Set test period
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
MS SETTINGS
→
OK
→
GPRS SETTINGS
→
OK
→
TEST PERIOD
→
OK
→
tteessttpp
→
OK
Value:
aaaa
– 4-digit administrator password;
tteessttpp
– test period, range – [0... 65535]
seconds.
EKB3
Enter parameter 46 and number of attempts:
46 tteessttpp #
Value:
tteessttpp
– test period, range – [0... 65535] seconds.
Example:
46120#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
NOTE:
0 value disables test period.
Unit ID is a 4-digit number (By default – 0000) required to identify the alarm system unit by ESR100 digital receiver or EGR100 middle-ware.
It is MANDATORY to change the default Unit ID before using ESR100 or EGR100.
Set unit ID
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
MS SETTINGS
→
OK
→
GPRS SETTINGS
→
OK
→
UNIT ID
→
OK
→
unid
→
OK
Value:
aaaa
– 4-digit administartor password;
unid
– 4-digit unit ID number.
EKB3
Enter parameter 47 and unit ID number:
47 unid #
Value:
unid
– 4-digit unit ID number.
Example:
472245#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
View GPRS network
settings
SMS
SMS text message content:
ssss_SETGPRS?
Example:
1111_SETGPRS?
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
NOTE:
Kronos NET/Kronos LT software communicates via TCP protocol, while EGR100 middle-ware v1.2 and up supports both – TCP and UDP
protocols. However, TCP protocol is NOT recommend to use with EGR100.
ATTENTION:
It is necessary to restart the system locally by powering down and powering up the system the system or remotely (see
32.
REMOTE SYSTEM RESTART
) after changing the IP address or switching from TCP to UDP.
30.2.2. Voice Calls and SMS
The system supports up to 3 monitoring station phone numbers for communication with the alarm system by Voice Calls or SMS commu-
nication method. Tel. Number 1 is mandatory, the other two can be used as backup phone numbers and are not necessary. The supported
phone number format is the following:
• International (w/o plus)
– The phone numbers must be entered starting with an international country code in the following format:
[international code][area code][local number], example for UK:
44170911XXXX1
.
To set up the system for data transmission via Voice Calls or SMS, please follow the basic configuration steps:
1. Enable MS Mode parameter (see
30. MONITORING STATION
).
2. Set 4-digit Account number (see
30. MONITORING STATION
).
3. Set Tel. Number 1... 3.
Set monitoring station
phone number
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
MS SETTINGS
→
OK
→
VOICE CALLS/SMS ST
→
OK
→
TEL. NUMBER 1... 3
→
OK
→
ttteeellnnuumm
→
OK
Value:
aaaa
– 4-digit administrator password;
ttteeellnnuumm
– up to 15 digits monitoring
station phone number.
EKB3
Enter parameter 26, phone number slot and phone number
:
26 ps ttteeellnnuumm #
Value:
ps
– phone number slot, range – [01... 03];
ttteeellnnuumm
– up to 15 digits monitor-
ing station phone number.
Example:
260144170911XXXX1#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.