MANUAL ELDES ESIM264 V3.2
MANUAL ELDES ESIM264 V3.2
2.3.3. Siren
RED +
BLACK -
BELL- BELL+
SIREN/BELL
1A max.
8
Piezo siren
1 Connect positive siren wire (red) to
BELL+
ter-
minal.
2 Connect negative siren wire (black) to
BELL-
terminal.
+12V
GND
BELL
BELL-
CO
M
BELL+
SIREN/BELL
1A max.
9
Self-contained siren
1 Connect negative
GND
siren wire to
COM
termi-
nal.
2 Controlling
BELL
siren wire must be connected
to
BELL-
terminal.
3 Connect positive
+12V
siren wire to
BELL+
ter-
minal.
See also
20. WIRED SIREN/BELL
.
NOTE:
BELL- is the commuted terminal intended for siren control.
2.3.4. iButton Key Reader and Buzzer
BUZ- BUZ+
+
-
DATA CO
M
BUZZER
iButton
key reader
DS1990A
10
Supported iButton key model:
Maxim/Dallas
DS1990A
The iButton key reader can be installed with buzzer
or separately. The buzzer is intended for audio in-
dication of exit/entry delay countdown providing
short beeps.
1 Connect iButton key reader terminal wires to
1-Wire interface:
COM
and
DATA
terminals re-
spectively.
2 Connect buzzer‘s negative terminal wire to
BUZ-
and positive terminal wire to
BUZ+.
NOTE:
The installation of buzzer is not necessary if EKB2/EKB3 keypad is used.
ATENTION:
The cable length for connection to 1-Wire interface can be up to 30m (98.43ft) max.
2.3.5. Temperature Sensor and iButton Key Reader
Supported iButton key model:
Maxim/Dallas DS1990A
Supported temperature sensor model:
Maxim/Dallas DS18S20, DS18B20
CO
M
DATA +5V
GND
DATA
+5V
iButton
key reader
DS1990A
Temperature
sensor
DS18S20
whit
e
br
own
CO
M
DATA +5V
GND
+5V
DATA
Temperature sensor
DS18S20
GND DATA +5V
CO
M
DATA +5V
black
yello
w
re
d
Digital thermometer
with 3m (9.84ft) wire
Vinson DS18B20
11
1 Depending on the model, connect tempera-
ture sensor
GND
/black wire,
DATA
/yellow
wire,
+5V
/red wire terminals to 1-Wire inter-
face:
COM
,
DATA
and
+5V
terminals respec-
tively.
2 When connecting iButton key reader in par-
allel to temperature sensor, connect iButton
key rea der terminal wires to
COM
and
DATA
terminals respectively.
ATENTION:
The cable length for connec-
tion to 1-Wire interface can be up to 30m
(98.43ft) max.
2.3.6. Relay Finder 40.61.9.12 with Terminal Socket 95.85.3 to PGM Output
Example of relay wiring for negative PGM output control
A1
C1
AUX+
A2
COIL
RELAY
12
1 Wire up relay
A1
terminal to PGM output
Cx
and
A2
terminal to
AUX+
.
2 In addition, connect the switching diode to re-
lay‘s
A2
and
A1
terminals.
NOTE:
We highly recommend using switching
diode model 1N4148 or similar.