16. TAMPERS
The tamper circuit is a single closed loop such that a break in the loop at any point will cause a tamper alarm regardless of the system
status – armed or disarmed. During the tamper alarm, the system will activate the siren/bell and the keypad buzzer and send the SMS text
message to the listed user phone number. The system will cause tamper alarm under the following conditions:
• If the enclosure of a detection device, siren/bell, metal cabinet or keypad is opened, the physical tamper switch will be triggered. By
default, indicated as
Tamper x
in the SMS text message (x = tamper number).
• If the wireless signal is lost due to low signal level or low battery power on a certain wireless device (see
19.3. Wireless Signal Status
Monitoring
).
By default, tamper alarm notification by SMS text message is enabled. To disable/enable tamper alarm notification, please refer to the
following configuration methods.
Disable tamper alarm
notification
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
TAMPER EVENT
→
OK
→
DISABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 25, event number and parameter status value:
25 08 0 #
Example:
25080#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
Enable tamper alarm
notification
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
TAMPER EVENT
→
OK
→
ENABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 25, event number and parameter status value:
25 08 1 #
Example:
25081#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
For more details on how to view violated tamper, please refer to
17. ALARM INDICATIONS AND NOTIFICATIONS FOR USER
16.1. Tamper Names
Each tamper has a name that can be customized by the user. The tamper names are used in SMS text messages that are sent to the user
during the tamper alarm. By default, the tamper names are:
Tamper 1, Tamper 2, Tamper 3, Tamper 4 etc
. To set a different tamper name,
please refer to the following configuration methods.
Manage tamper name
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
17. ALARM INDICATIONS AND NOTIFICATIONS FOR USER
When a zone, depending on zone type (see
14.5. Zone Type Definitions
), or tamper is violated, the system will cause an alarm. By de-
fault, the alarm duration is 1 minute (see
20. SIREN/BELL
regarding the alarm duration). During the alarm, the system will follow this
pattern:
1. The system activates the siren/bell and the keypad buzzer.
a) The siren/bell will emit pulsating sound if the violated zone is of Fire type, otherwise the sound will be steady.
b) The keypad buzzer will emit short beeps.
c) Depending on violated zone type, EKB2 keypad will display
BURGLARY ALARM
message followed by one of the alarm messages in the
home screen view:
• ALARM.
• FIRE ALARM.
• 24H ALARM.
d) During the tamper alarm, EKB2 keypad will display
TAMPER ALARM
message in the home screen view.
e) If one or more zones are violated, EKB3 will light ON the corresponding violated zone indicator (-s) ranging from 1 through 12. Indica-
tor SYSTEM will flash if one or more high-numbered zones are violated. If one or tampers are violated, indicator SYSTEM will light ON.
For more details on viewing violated high-numbered zone and tamper numbers by EKB3 keypad, please refer to
29. INDICATION OF
SYSTEM FAULTS.
2. The system attempts to send an SMS text message, containing the violated zone/tamper name (see
14.8. Zone Names
on how to set
a zone name), to the first listed user phone number, sharing the same partition as the violated zone/tamper. The system will send SMS
text messages regarding each violated zone/tamper separately.
a) If the user phone number is unavailable and the system fails to receive the SMS delivery report during 45 seconds, it will attempt to
send the SMS text message to the next listed user phone number, assigned to the same partition as the previous one. The user phone
number may be unavailable due to the following reasons:
• mobile phone was switched off.
• was out of GSM signal coverage.
b) The system will continue sending the SMS text message to the next listed user phone numbers in the priority order until one is availa-
ble. The system sends the SMS text message only once and will not return to the first user phone number if the last one was unavaila-
ble.
3. By default, the system attempts to ring the first user phone number, sharing the same partition as the violated zone/tamper. The system
will dial regarding each violated zone/tamper separately.
a) When the call is answered, the user will be able to listen on the mobile phone for approx. 30 seconds to what is happening in the area,
surrounding the alarm system. This feature will be available only if a microphone is connected to the system (see
25. REMOTE LIS-
TENING AND 2-WAY VOICE COMMUNICATION
).
b) The system will dial the next listed user phone number, assigned to the same partition, if the previous user was unavailable due to the
following reasons:
• mobile phone was switched off.
• mobile phone was out of GSM signal coverage.
• provided “busy” signal.
• user did not answer the call after several rings, predetermined by the GSM operator.
c) The system will continue dialling the next listed user phone numbers in the priority order until one is available. The system dials only
once and will not return to the first user phone number if the last one was unavailable.
d) The system will not dial the next listed user phone number if the previous one was available, but rejected the phone call.
To silent the siren/bell as well as to cease system phone calls and SMS text message sending to the user phone numbers, please disarm the
system (see
12. ARMING AND DISARMING
).
View violated zones
SMS
SMS text message content:
ssss_INFO
Value:
ssss – 4-digit SMS password.
Example:
1111_INFO
EKB2
Menu path:
OK
→
VIOLATED ZONES
→
OK
→
ZONE 1... 44