MANUAL ELDES ESIM264 V3.2
MANUAL ELDES ESIM264 V3.2
ATTENTION:
NEVER add a phone number of the device’s SIM card as a user phone number!
ATTENTION:
Once User 1 phone number is set, it will be restricted to modify it only.
NOTE:
Multiple user phone numbers can be set by a single SMS text message,
Example:
1111_NR1:44170911XXXX1_
NR2:44170911XXXX2_ NR5:44170911XXXX3
NOTE:
Multiple user phone numbers can be deleted by a single SMS text message,
Example
:
1111_NR2:DEL_NR3:DEL
8.1. System Control from any Phone Number
By default, once a user phone number is listed, the system ignores any incoming calls and SMS text messages from a non-listed phone
number as well as it rejects the SMS text messages containing wrong SMS password even from a listed user phone number. To permit/deny
system arming/disarming by phone call and SMS text message that contain a valid SMS password, configuration by SMS text message that
contain a valid SMS password from any phone number, please refer to the following configuration methods.
Enable system control
from any phone
number
SMS
SMS text message content:
ssss_STR:ON
Value:
ssss
– 4-digit SMS password.
Example:
1111_STR:ON
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
PRIMARY SETTINGS
→
OK
→
CALL/SMS
SETTINGS
→
OK
→
CTRL FROM ANY NUM
→
OK
→
ENABLE
→
OK
Value:
aaaa –
4-digit administrator password.
EKB3
Enter parameter 12 and parameter status value:
12 1 #
Example:
121#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
Disable system
control from any
phone number
SMS
SMS text message content:
ssss_STR:OFF
Value:
ssss
– 4-digit SMS password.
Example:
1111_STR:OFF
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
PRIMARY SETTINGS
→
OK
→
CALL/SMS
SETTINGS
→
OK
→
CTRL FROM ANY NUM
→
OK
→
DISABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 12 and parameter status value:
12 0 #
Example:
120#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
9. DATE AND TIME
The system comes equipped with internal real-time clock (RTC) that keeps track of the current date and time. Once the system is up and
running, the user must set the correct date and time, otherwise the system will not operate properly. After shutting down and starting up
the system, the date and time must be set again.
Set date and time
SMS
SMS text message content:
ssss_yyyy.mm.dd_hr:mn
Value:
ssss
– 4-digit SMS password;
yyyy
– year;
mm
– month, range – [01... 12];
dd
– day,
range – [01... 31];
hr
– hours, range – [00... 23];
mn
– minutes, range – [00... 59].
Example:
1111_2015.03.16_14:33
EKB2
Menu path:
a)
OK
→
DATE/TIME SETTINGS
→
OK
→
yyyy-mm-dd hr:mn
→
OK
b)
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
PRIMARY SETTINGS
→
OK
→
DATE/TIME
SETTINGS
→
OK
→
yyyy-mm-dd hr:mn
→
OK
Value:
aaaa
– 4-digit administrator password;
yyyy
– year;
mm
– month, range – [01... 12];
dd
– day, range – [01... 31];
hr
– hours, range – [00... 23];
mn
– minutes, range – [00... 59].
EKB3
Enter parameter 66, date and time:
66 yyyy mm dd hr mn#
Value:
yyyy
– year;
mm
– month, range – [01... 12];
dd
– day, range – [01... 31];
hr
– hours,
range – [00... 23];
mn
– minutes, range – [00... 59].
Example:
66201505291235#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
NOTE:
When the system is connected to the monitoring station via GPRS network connection, the date and time will be automatically
synchronized with the monitoring station upon the system startup.