MANUAL ELDES ESIM264 V3.2
MANUAL ELDES ESIM264 V3.2
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
20.3. Indication by EWS3 - Wireless Indoor Siren Indicators
When enabled, the built-in LED indicators of EWS3 wireless indoor siren will flash during the alarm. In the event of burglary, 24-hour or
tamper alarm, EWS3 will flash the blue LED indicators, while in case of a fire alarm, the device can flash the red LED indicator. To enable/
disable these features, please refer to the following configuration methods.
Enable EWS3 LED
indication
EKB2
Menu path:
Burglary/24-hour/tamper alarm LED:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
PRIMARY
SETT INGS
→
OK
→
SIREN SETTINGS
→
OK
→
EWS3 ALARM
→
OK
→
ENABLE
→
OK
Fire alarm:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
PRIMARY SETT INGS
→
OK
→
SIREN
SETTINGS
→
OK
→
EWS3 FIRE LED
→
OK
→
ENABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 94/93 and parameter status value:
Burglary/24-hour/tamper alarm LED:
94 1 #
Fire alarm LED:
93 1 #
Example:
931#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
Disable EWS3 LED
indication
EWS3
Menu path:
Burglary/24-hour/tamper alarm
LED: OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
PRIMARY
SETT INGS
→
OK
→
SIREN SETTINGS
→
OK
→
EWS3 ALARM
→
OK
→
DISABLE
→
OK
Fire alarm LED:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
PRIMARY SETT INGS
→
OK
→
SIREN SETTINGS
→
OK
→
EWS3 FIRE LED
→
OK
→
DISABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 94/93 and parameter status value:
Burglary/24-hour/tamper alarm LED:
94 0 #
Fire alarm LED:
93 0 #
Example:
940#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
21. BACKUP BATTERY, MAINS POWER STATUS MONITORING AND MEMORY
21.1. Backup Battery Status Monitoring
The system may come equipped with a backup battery maintaining power supply of the system when the mains power supply is temporally
lost. The implemented feature allows the system to perform a self-test on the backup battery and notify the listed user phone number by
SMS text message as well as to indicate system fault by the keypad (see
29. INDICATION OF SYSTEM FAULTS
) if:
• battery has failed and requires replacement – battery resistance is 2Ω or higher; self-tested every 24 hours.
• battery power is running low – battery voltage is 10.5V or lower; constantly self-tested.
By default, all notifications regarding the backup battery status are enabled. To disable/enable a determined backup battery notification,
please refer to the following configuration methods.
Disable Battery Failed
notification
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
BATTERY FAIL EVENT
→
OK
→
DISABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 25, notification number and parameter status value:
25 09 0 #
Example:
25090#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
Enable Battery Failed
notification
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
BATTERY FAIL EVENT
→
OK
→
ENABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 25, notification number and parameter status value:
25 09 1 #
Example:
25091#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
Disable Low Battery
notification
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
LOW BATTERY EVENT
→
OK
→
DISABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 25, notification number and parameter status value:
25 06 0 #
Example:
25060#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
Enable Low Battery
notification
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
LOW BATTERY EVENT
→
OK
→
ENABLE
→
OK
Value:
aaaa
– 4-digit administrator password.