For zone wiring diagrams of the 6-Zone mode, please refer to
2.3.2. Zone Connection Types
.
Set zone connection
type for 6-Zone mode
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
ZONE TYPE:6-ZONE M
→
OK
→
TYPE 1... 3
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 39 and number of zone connection type:
39 1 #
– Type 1
39 2 #
– Type 2
39 3 #
– Type 3
Example:
392#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
NOTE:
The system supports a mixed combination of Type 1 and Type 2 zone connection types simultaneously regardless of the type (Type 1
or Type 2) selected in the system’s configuration. This applies to on-board zones, keypad zones and EPGM1 zones.
Example:
On-board zone
Z1 and keypad zone is wired based on Type 1, while on-board zone Z3 and EPGM1 zone is wired based on Type 2.
NOTE:
Type 3 is NOT supported by keypad zones.
NOTE:
ATZ mode is NOT supported by keypad zones and EPGM1 zones. If ATZ mode is enabled, EPGM1 zones must be wired in accordance
with the last selected 6-Zone mode zone connection type before the ATZ mode has been enabled. The ATZ mode setting does NOT affect the
zone connection type of the keypad zones.
14.4. ATZ (Advanced Technology Zone) Mode
The ATZ mode is a software-based feature that doubles the number of on-board zones and enables two detection devices to be installed
per 1 zone terminal. Once this mode is enabled, the zone connection Type 4 is set automatically. The detection devices must be wired to the
on-board zone terminals as indicated in the wiring diagram of the associated zone connection type.
Available zone connection types for the ATZ mode:
• Type 4
– Parallel wiring of 2 NC (normally-closed) detection devices with 5,6kΩ and 3,3kΩ EOL (end-of-line) resistors respectively.
5,6kΩ EOL resistor corresponds to zones ranging from Z1 through Z6, while 3,3kΩ EOL resistor corresponds to zones ranging from Z7
through Z12.
• Type 5
– Combination of serial and parallel wiring of tamper with 5,6kΩ EOL resistor and 2 NC (normally-closed) detection devices with
5,6kΩ and 3,3kΩ EOL resistors respectively. 5,6kΩ EOL resistor corresponds to zones ranging from Z1 through Z6, while 3,3kΩ EOL
resistor corresponds to zones ranging from Z7 through Z12.
For zone wiring diagrams of the ATZ mode, please refer to
2.3.2. Zone Connection Types
.
Enable ATZ mode
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
ATZ MODE
→
OK
→
ENABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 28 and parameter status value:
28 1 #
Example:
281#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
Disable ATZ mode
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
ATZ MODE
→
OK
→
DISABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 28 and parameter status value:
28 0 #
Example:
280#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
Set zone connection
type for ATZ mode
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
ZONE TYPE:ATZ MODE
→
OK
→
TYPE 4... 5
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 38 and number of zone connection type:
38 1 #
– Type 4
38 2 #
– Type 5
Example:
381#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
NOTE:
Once enabled, the ATZ mode DOES NOT affect EPGM1 zones, nor keypad zones and applies to on-board zones only.
14.5. Zone Type Definitions
• Interior Follower
– The zone can be violated during exit and entry delay without causing an alarm. If the zone is violated before the
entry delay has begun, it will cause an instant alarm followed by single notification delivery even if the zone has been violated multiple
times or another Interior Follower-type zone has been violated while alarm period (by default - 1 minute) is in progress. Typically, this
zone is used for indoor protection devices, such as motion detectors, installed close to the exit/entry doors.
• Instant
– The alarm is instantly caused if this zone is violated when the system is armed or during entry delay. This zone type is usually
used for doors, windows, shock sensors or other zones.
• 24-Hour
– When the system is either armed or disarmed, the zone will cause instant alarm if violated. Normally, this type of zone is
used for securing the areas that require constant supervisory.
• Delay
– This zone type can be violated during exit and entry delay without causing an alarm. If the zone is violated when the system
is armed, it will initiate entry delay countdown intended for the user to disarm the system. If the zone is left violated after the exit
delay expires, it will cause an instant alarm. Typically, this zone type is used for door contacts installed at designated exit/entry doors.
• Fire
– If this zone type is violated when the system is either armed or disarmed, the alarm will be instantly caused and the siren/bell will
emit pulsating sound. Typically, this zone type is used for flame and smoke detectors.
• Panic/Silent
– This zone operates the same as 24-Hour zone type, but the system will not activate the siren/bell and keypad buzzer if
violated. Normally, this zone type used for panic alarm buttons.
Set zone type for
individual zone
EKB2
Menu path:
On-board zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
ONBOARD
ZONES
→
OK
→
ZONE 1... 12
→
OK
→
TYPE
→
OK
→
INTERIOR FOLLOWER | INSTANT | 24-
HOUR | DELAY | FIRE | PANIC/SILENT
→
OK
Wireless zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
WIRELESS
ZONES 1... 4
→
OK
→
WLESS ZONE 1... 16
→
OK
→
TYPE
→
OK
→
INTERIOR FOLLOWER |
INSTANT | 24-HOUR | DELAY | FIRE | PANIC/SILENT
→
OK
Keypad zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
KEYPAD ZONES
→
OK
→
KEYPAD 1... 4 ZONE
→
OK
→
TYPE
→
OK
→
INTERIOR FOLLOWER | INSTANT | 24-
HOUR | DELAY | FIRE | PANIC/SILENT
→
OK
EPGM1 zone:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
ZONES
→
OK
→
EPGM1 ZONES
→
OK
→
EPGM1 ZONE 1... 16
→
OK
→
TYPE
→
OK
→
INTERIOR FOLLOWER | INSTANT | 24-HOUR |
DELAY | FIRE | PANIC/ SILENT
→
OK
Value:
aaaa
– 4-digit administrator password.