ZT-Mains-H5 AC/DC heat alarm 

 

 

 

Cautions 

 

ELECTRICAL HAZARD: 

Disconnect power from equipment prior to making any 

internal adjustments. Service should only be performed by qualified personnel. 

PRODUCT LIMITATIONS

: This heat alarm does not detect smoke, gas, or flame, 

and should not be covered with a guard or similar obstructing item. 

Hazardous levels of smoke and toxic gas can build up before a heat alarm might 

operate. Where life safety is the primary requirement in the event of a fire, smoke, gas or 
combination alarms usually provide earlier warning than heat alarms alone. 

This heat alarm may not alert people who are hearing impaired. It is strongly recommended 
that the special-purpose heat alarms using visual or vibrating alerting devices, should be 
installed for these occupants. 

This heat alarm may not be effective in fires where heat is prevented from reaching the device 
(eg where intermediate doors are closed), where the fire grows so rapidly that the egress path 
is blocked (even when correctly located), and where the fire is intimate to a person (eg where 
a victim's clothes catch fire). 

SLEEPING AREAS

: Heat alarms should not replace required smoke alarms in 

sleeping areas. 

INSTALLATION LIMITATIONS

 This product is designed for use in a single 

residential unit, such as a family home or apartment. Heat alarms, located outside 
the dwelling may not provide early warning to occupants. 

This product is not designed for use in non-residential buildings. Non-residential buildings 
require special fire detection and alarm systems. This product alone is not a suitable 
substitute for a fire detection system installed in places of work or where people sleep on a 
temporary basis, such as hotels or motels, dormitories, hospitals, nursing homes or group 
homes of any kind, even if they were once dwellings. Please refer to local regulations for fire 
detection and alarm system requirements.  

 

Features 

 

ZT-Mains-H5 AC/DC heat alarms provide AC mains, DC or AC/DC powered 
heat detection and alarm functions within a single product. A single battery 
(available with some models) will ensure that the heat alarm remains operational, 
even if mains power is temporarily unavailable. 

ZT-Mains-H5 AC/DC heat alarms are suitable for general residential applications 
where a smoke alarm may result in unwanted activation (eg kitchens, garages 
with exhaust fumes, and areas subject to high levels of dust and other air-borne 
contaminants). 

ZT-Mains-H5 AC/DC heat alarms provide home owners with an easy-to-install, 
premium solution for property protection. 

Audible and Visual Alarm Indicators (all models) 

When operating normally, a red LED in the Test button will flash every 32 s. 
When heat is detected, an internal sounder will activate to alert occupants, and 
the LED will flash rapidly. The sounder is a loud, pulsating alarm. 

Test Button (all models) 

Pressing and holding the Test button for 5 s will activate the heat alarm to 
check its operation. The alarm will sound and the LED will flash rapidly. 
Releasing the test button will return the unit to normal operation. 

Low Battery (battery models only) 

When the battery is depleted, the heat alarm will emit a short audible signal 
every 32 s for at least 30 days. When the Low Battery signal is given, change 
the battery without delay. 

Interconnection Terminals (where fitted) 

Interconnected heat alarms will activate sounders on all units if any heat alarm 
detects heat. In this case, only the heat alarm(s) that detected heat will flash the 
LED. This allows the home owner to quickly locate the cause of the alarm. Up to 
25 units can be interconnected as long as the cabling is less than 250 m in 
length. Interconnection terminals are only available on some models. 

 

Specifications

 

 
Mains power source

 

AC 220 V ~ AC 240 V, 50/60 Hz 

Battery power source

 

DC 9 V 

Operating temperature 

°

C ~ +49 

°

C

Operating humidity 

10 % ~ 90 % RH, non-condensing 

Alarm sounder output 

≥ 85 dB @ 3 m 

Interconnection (max) 

25 units, 250 m cabling 

a

 Can transit to higher temperatures for alarm operation. 

 

Installation Preparation

 

 

Equipment 

Before commencing installation, ensure all equipment and tools to mount and 
test the device are available, such as drills, mounting screws (supplied), cables 
and ladders. 

Location Selection in Homes and Apartments 

Heat alarms are suitable for residential applications where smoke or gas 
detectors may cause unwanted alarms. The following locations are suitable for 
heat alarms. 

 

Areas where combustion particles are present, such as kitchens with few 
windows or poor ventilation. 

 

Garages where there may be vehicle exhaust fumes. 

 

Near furnaces, combustion heaters, and space heaters. 

 

Damp or very humid areas, such as bathrooms with showers. 

 

Dusty or dirty areas. 

 

Insect-infested areas. 

WARNING

: Hazardous levels of smoke and toxic gas can build up 

before a heat alarm might operate. Where life safety is the primary 
requirement in the event of a fire, smoke, gas or combination alarms 

usually provide earlier warning than heat alarms alone.  

For complete coverage, smoke alarms should be installed in all rooms, halls, 
storage areas, basements, and attics in dwellings. The minimum coverage is 
one smoke alarm on each floor and one outside each sleeping area.  

Installation Location 

Install heat alarms as close to the centre of the ceiling as possible, away from 
light fittings and air-conditioning ducts. If this is not practical, mount the heat 
alarm on the ceiling, no closer than 50 cm from any wall or corner (see Fig. 1). 

 

 

Fig. 1 

– Heat alarm location from walls

 

 

 

If some of your rooms have sloped, peaked, or gabled ceilings, try to mount 
heat alarms 0.9 m measured horizontally from the highest point of the ceiling 
as shown in Fig. 2. 

 

 

Fig. 2 

– Heat alarm location for gabled ceilings

 

 

 

Where Not to Install Your Heat alarm 

Heat alarms are not a suitable substitute for smoke alarms required in sleeping 
areas.  

 

Installation and Test

 

 

Please read the previous section 

Installation Preparation

, before 

commencing installation. 

WARNING

: Do not connect this heat alarm to any device other than 

another ZT-Mains-H5 heat alarm(where the interconnection facility is 

provided) Connecting anything else to this heat alarm may prevent it from 
working properly.  

Follow these steps to install your heat alarm. 

Installing the Battery (DC and AC/DC models) 

NOTE: The battery is purposefully reversed during production to keep it fresh 
until installation.  

1. 

Remove the battery (supplied) from the battery compartment on the 
underside of the heat alarm, and correctly fit it in the battery 
compartment (see Fig. 3). 

 

 

Fig. 3 

– Battery compartment

 

 

 

 

NOTE: The battery will snap into place and should not shake loose. 

WARNING

: If the battery is not installed, the battery compartment will 

not close and the heat alarm will not function.  

NOTE: When the heat alarm battery is first contacted, the alarm sounder may 
sound for 1 s. This is normal and indicates that the battery is positioned 
properly.  

2. 

Close the battery cover. 

 