GEO3.5 MANUAL 35
PULL TM PARAMETER
The PULL TM parameter is used to set the minimum amount of time that the trigger must be pulled before it is recognised as
a valid trigger pull. This parameter can be set between 3.0 and 20.0 milliseconds in 0.1ms increments.
RELEASE TM PARAMETER
The RELEASE TM parameter is used to set the minimum amount of time that the trigger must be released before it is
recognised as a valid trigger release. This parameter can be set between 3.0 and 25.0 milliseconds in 0.1ms increments.
PULL PT PARAMETER
The PULL PT parameter is only available if OPTO has been selected in the Hardware menu. PULL PT defines the point at
which the trigger is considered pulled and is adjustable between 51% and 99% in 1% increments.
RELEASE PT PARAMETER
The RELEASE PT parameter is only available if OPTO has been selected in the Hardware menu. RELEASE PT defines the
point at which the trigger is considered released and is adjustable between 1% and 49% in 1% increments.