Appendix A—Parameter ID list
POWERXL SERIES VFD
MN040010EN—June 2018 www.eaton.com
Menu
Item
No.
Modbus
Register
PROFIBUS
EtherNet/IP
DeviceNet
Parameter
Description
Data
Type
Length
(in Bytes)
Display
Format
PNU
PNU
SubIndex
Class Instance Attribute Class Instance Attribute
P3.30
351
410
0
160
1
99
164
1
30
PID1 Set Point Select
BYTE
1
x0
P3.31
352
410
1
160
1
100
164
1
31
PID2 Set Point Select
BYTE
1
x0
P3.32
199
400
8
160
1
101
164
1
32
Jog Enable
BYTE
1
x0
P3.33
224
3104
0
160
1
102
164
1
33
Start Timer 1
BYTE
1
x0
P3.34
225
3104
1
160
1
103
164
1
34
Start Timer 2
BYTE
1
x0
P3.35
226
3104
2
160
1
104
164
1
35
Start Timer 3
BYTE
1
x0
P3.36
208
415
0
160
1
105
164
1
36
AI Ref Source Select
BYTE
1
x0
P3.37
210
1910
0
160
1
106
164
1
37
Motor Interlock 1
BYTE
1
x0
P3.38
211
1910
1
160
1
107
164
1
38
Motor Interlock 2
BYTE
1
x0
P3.39
212
1910
2
160
1
108
164
1
39
Motor Interlock 3
BYTE
1
x0
P3.40
213
1910
3
160
1
109
164
1
40
Motor Interlock 4
BYTE
1
x0
P3.41
214
1910
4
160
1
110
164
1
41
Motor Interlock 5
BYTE
1
x0
P3.42
747
400
2
160
1
111
164
1
42
Emergency Stop
BYTE
1
x0
P3.43
1246
1804
0
160
1
113
164
1
43
Bypass Overload
BYTE
1
x0
P3.44
2119
NA
NA
164
1
76
164
1
44
Fire Mode Direction
Invert
BYTE
1
x0
P3.45
2206
NA
NA
NA
NA
NA
NA
NA
NA
IO Terminal 2 Start
Stop Logic
BYTE
1
x0
P3.46
2207
NA
NA
NA
NA
NA
NA
NA
NA
IO Terminal 2 Start
Signal 1
BYTE
1
x0
P3.47
2208
NA
NA
NA
NA
NA
NA
NA
NA
IO Terminal 2 Start
Signal 2
BYTE
1
x0
P3.48
2293
NA
NA
NA
NA
NA
NA
NA
NA
Ext. Fault 2 NO
BYTE
1
x0
P3.49
2294
NA
NA
NA
NA
NA
NA
NA
NA
Ext. Fault 2 NC
BYTE
1
x0
P3.50
2295
NA
NA
NA
NA
NA
NA
NA
NA
Ext. Fault 3 NO
BYTE
1
x0
P3.51
2296
NA
NA
NA
NA
NA
NA
NA
NA
Ext. Fault 3 NC
BYTE
1
x0
P3.52
2297
NA
NA
NA
NA
NA
NA
NA
NA
Ext. Fault 1 Text
BYTE
1
x0
P3.53
2298
NA
NA
NA
NA
NA
NA
NA
NA
Ext. Fault 2 Text
BYTE
1
x0
P3.54
2299
NA
NA
NA
NA
NA
NA
NA
NA
Ext. Fault 3 Text
BYTE
1
x0
P3.55
2312
NA
NA
NA
NA
NA
NA
NA
NA
Parameter Set1/2 Sel
BYTE
1
x0
P3.56
2394
NA
NA
NA
NA
NA
NA
NA
NA
Deragging Enable
BYTE
1
x0
P3.57
2395
NA
NA
NA
NA
NA
NA
NA
NA
HOA On/Off
BYTE
1
x0
P4.1
227
276
0
160
1
114
165
1
1
AO1 Mode
BYTE
1
x0
P4.2
146
460
0
160
1
116
165
1
2
AO1 Function
BYTE
1
x0
P4.3
149
279
0
160
1
117
165
1
3
AO1 Minimum
BYTE
1
x0
P4.4
147
277
0
160
1
118
165
1
4
AO1 Filter Time
INTEGER
2
x100
P4.5
150
274
0
160
1
119
165
1
5
AO1 Scale
INTEGER
2
x0
P4.6
148
278
0
160
1
120
165
1
6
AO1 Inversion
BOOLEAN 1
x0
P4.7
173
275
0
160
1
121
165
1
7
AO1 Offset
INTEGER
2
x100
P4.8
228
276
1
160
1
115
165
1
8
AO2 Mode
BYTE
1
x0
P4.9
229
460
1
160
1
122
165
1
9
AO2 Function
BYTE
1
x0
P4.10
232
279
1
160
1
123
165
1
10
AO2 Minimum
BYTE
1
x0
P4.11
230
277
1
160
1
124
165
1
11
AO2 Filter Time
INTEGER
2
x100
P4.12
233
274
1
160
1
125
165
1
12
AO2 Scale
INTEGER
2
x0
P4.13
231
278
1
160
1
126
165
1
13
AO2 Inversion
BOOLEAN 1
x0
P4.14
234
275
1
160
1
127
165
1
14
AO2 Offset
INTEGER
2
x100
P5.1
151
461
0
160
1
128
166
1
1
DO1 Function
BYTE
1
x0
P5.2
152
451
0
160
1
129
166
1
2
RO1 Function
BYTE
1
x0
P5.3
153
451
1
160
1
130
166
1
3
RO2 Function
BYTE
1
x0
P5.4
538
451
2
160
1
131
166
1
4
RO3 Function
BYTE
1
x0
Table 205. DG1 Parameter ID list, continued
Summary of Contents for PowerXL Series
Page 1: ...Effective June 2018 Supersedes October 2017 Communication manual PowerXL Series VFD...
Page 24: ...xxiv S curit du moteur et de l quipement POWERXL SERIES VFD MN040010EN June 2018 www eaton com...
Page 254: ...230 Hardware speci cation POWERXL SERIES VFD MN040010EN June 2018 www eaton com...
Page 255: ...231 Hardware speci cation POWERXL SERIES VFD MN040010EN June 2018 www eaton com...