155
SmartWire-DT External Communication Cards
POWERXL SERIES VFD
MN040010EN—June 2018 www.eaton.com
Table 188. SmartWire-DT parameters
Code
Parameter
Min.
Max.
Unit
Default
ID
Note
B19
Terminal: SWD
B19.1
Monitor
B19.1.1
Device Parameters
BX.1.1.1
Board Status
0
B0 = DCOM Comm. Fault
B1 = Board HW Fault
B2 = NA for SMDT card
B3 = Fieldbus Fault
B4 = Reserved
BX.1.1.2
Firmware
Version
V1.01.0009
BX.1.1.3
Protocol
Status
0
0=Not
Configured
1=Operational
2=Diagnostics
BX.1.1.4
Operation Mode
0
0=PD2x16Bit Profile
1=8Bit Profile
2=1-0-A Switch
BX.1.1.5
PDP-Telegram Selection
1
1
1
1=Standard Telegram 1
BX.1.1.6
Fault Counter PDP
0
65535
BX.1.1.7
Fault Situations Max
8x8
BX.1.1.8
PDP-Profil Number
341
BX.1.1.9
PDP-Control Word
0x0000
0xFFFF
BX.1.1.10
PDP-Status Word
0x0000
0xFFFF
BX.1.2
Parameter Access
BX.1.2.1
PDP-MaxBlockLength
30
BX.1.2.2
PDP-NoOfMultiparameter
1
BX.1.2.3
PDP-MaxLatency
2
BX.1.3
DO Identification
BX.1.3.1
PDP-DO Manufacturer
0x019D
BX.1.3.2
PDP-DO Device Type
0x3000
BX.1.3.3
PDP-DO FW-Interface
01.03
BX.1.3.4
PDP-DO FW-Year
2017
BX.1.3.5
PDP-DO FW-DayMonth
1602
BX.1.3.6
PDP-DO NoOfDOs
1
BX.1.3.7
PDP-DO Subclass
1
BX.2
Parameters
BX.2.3
SWD. Card FB Fault Response
0
1
0
Summary of Contents for PowerXL Series
Page 1: ...Effective June 2018 Supersedes October 2017 Communication manual PowerXL Series VFD...
Page 24: ...xxiv S curit du moteur et de l quipement POWERXL SERIES VFD MN040010EN June 2018 www eaton com...
Page 254: ...230 Hardware speci cation POWERXL SERIES VFD MN040010EN June 2018 www eaton com...
Page 255: ...231 Hardware speci cation POWERXL SERIES VFD MN040010EN June 2018 www eaton com...