Appendix A—Parameter ID list
POWERXL SERIES VFD
MN040010EN—June 2018 www.eaton.com
Menu
Item
No.
Modbus
Register
PROFIBUS
EtherNet/IP
DeviceNet
Parameter
Description
Data
Type
Length
(in Bytes)
Display
Format
PNU
PNU
SubIndex
Class Instance Attribute Class Instance Attribute
M44
1686
NA
NA
164
1
57
160
1
44
Instant Motor Power
DOUBLE
4
x1000
M45
2120
NA
NA
164
1
77
160
1
45
Energy Savings
DOUBLE
4
x1000
M46
2209
NA
NA
NA
NA
NA
NA
NA
NA
Control Board DIDO
Status
INTEGER
2
x0
M47
2210
NA
NA
NA
NA
NA
NA
NA
NA
SlotA DIDO Status
INTEGER
2
x0
M48
2211
NA
NA
NA
NA
NA
NA
NA
NA
SlotB DIDO Status
INTEGER
2
x0
M49
29
NA
NA
160
1
43
NA
NA
NA
Application Status
Word
INTEGER
2
x0
M50
2414
NA
NA
NA
NA
NA
NA
NA
NA
Standard Status
Word
INTEGER
2
x0
M51
2445
NA
NA
NA
NA
NA
NA
NA
NA
Output
DOUBLE
4
x100
M52
2447
NA
NA
NA
NA
NA
NA
NA
NA
Reference
DOUBLE
4
x100
M53
601
520
2
162
1
13
185
1
3
Total MWh Count
DOUBLE
4
x10000
M54
603
522
0
162
1
14
185
1
4
Total Power Day
Count
INTEGER
2
x0
M55
606
821
1
162
1
15
185
1
5
Total Power Hr Count
DOUBLE
4
x0
M56
604
806
0
162
1
16
185
1
6
Trip MWh Count
DOUBLE
4
x10000
M57
636
870
0
162
1
18
185
1
8
Trip Power Day Count
INTEGER
2
x0
M58
637
871
0
162
1
19
185
1
9
Trip Power Hr Count
DOUBLE
4
x0
M59
30
329
0
160
1
45
160
1
46
Multi-Monitoring
BYTE
3
x0
P1.1
101
20
0
160
1
162
162
1
1
Min Frequency
INTEGER
2
x100
P1.2
102
20
1
160
1
163
162
1
2
Max Frequency
INTEGER
2
x100
P1.3
103
130
0
160
1
164
162
1
3
Accel Time 1
INTEGER
2
x10
P1.4
104
134
0
160
1
165
162
1
4
Decel Time 1
INTEGER
2
x10
P1.5
486
210
0
40
2
6
40
2
6
Motor Nom Current
INTEGER
2
x10
P1.6
489
217
0
40
2
15
40
2
15
Motor Nom Speed
INTEGER
2
x0
P1.7
490
215
0
161
1
116
162
1
7
Motor PF
INTEGER
2
x100
P1.8
487
211
0
40
2
7
40
2
7
Motor Nom Voltage
INTEGER
2
x0
P1.9
488
216
0
161
1
118
162
1
9
Motor Nom
Frequency
INTEGER
2
x100
P1.10
1685
NA
NA
164
1
56
162
1
10
Power Up Local
Remote Select
BYTE
1
x0
P1.11
135
408
0
160
1
150
162
1
11
Remote 1 Control
Place
BYTE
1
x0
P1.12
1695
NA
NA
164
1
63
162
1
12
Local Control Place
BYTE
1
x0
P1.13
2462
NA
NA
NA
NA
NA
NA
NA
NA
Bumpless Enable
BYTE
1
x0
P1.14
136
436
0
160
1
152
162
1
13
Local Reference
BYTE
1
x0
P1.15
137
437
0
160
1
153
162
1
14
Remote 1 Reference
BYTE
1
x0
P1.16
1679
622
3
164
1
53
162
1
15
Reverse Enable
BYTE
1
x0
P1.17
2423
NA
NA
NA
NA
NA
NA
NA
NA
Run Delay Time
INTEGER
2
x0
P1.18
2465
NA
NA
NA
NA
NA
NA
NA
NA
HOA Source
BYTE
1
x0
P2.1.1
144
35
1
160
1
50
163
1
21
AI Ref Scale Min
Value
INTEGER
2
x100
P2.1.2
145
34
1
160
1
51
163
1
22
AI Ref Scale Max
Value
INTEGER
2
x100
P2.2.1
222
263
0
160
1
52
163
1
1
AI1 Mode
BYTE
1
x0
P2.2.2
175
260
0
160
1
54
163
1
2
AI1 Signal Range
BYTE
1
x0
P2.2.3
176
264
0
160
1
55
163
1
3
AI1 Custom Min
INTEGER
2
x100
P2.2.4
177
265
0
160
1
56
163
1
4
AI1 Custom Max
INTEGER
2
x100
P2.2.5
174
266
0
160
1
57
163
1
5
AI1 Filter Time
INTEGER
2
x100
P2.2.6
181
267
0
160
1
62
163
1
6
AI1 Signal Invert
BOOLEAN 1
x0
P2.2.7
178
1711
0
160
1
63
163
1
7
AI1 Joystick Hyst
INTEGER
2
x100
Table 205. DG1 Parameter ID list, continued
Summary of Contents for PowerXL Series
Page 1: ...Effective June 2018 Supersedes October 2017 Communication manual PowerXL Series VFD...
Page 24: ...xxiv S curit du moteur et de l quipement POWERXL SERIES VFD MN040010EN June 2018 www eaton com...
Page 254: ...230 Hardware speci cation POWERXL SERIES VFD MN040010EN June 2018 www eaton com...
Page 255: ...231 Hardware speci cation POWERXL SERIES VFD MN040010EN June 2018 www eaton com...