98
PROFIBUS-DP External Communication Cards
POWERXL SERIES VFD
MN040010EN—June 2018 www.eaton.com
Table 117. Field coding, continued
Field
Data type
Value
Comment
Format
Unsigned 8
0x00
Reserved
Every slave shall at least support the data types Byte,
Word and Double Word (mandatory). Write requests
by the master preferable use the “correct” data types.
As substitute, Byte, Word, or Double Word are also possible.
The master shall be able to interpret all values/data types.
0x01…0x36
Data types
0x37…0x3F
Reserved
0x40
Zero
0x41
Byte
0x42 Word
0x43 Double
word
0x44 Error
0x45…0xFF
Reserved
No. of Values
Unsigned 8
0x00…0xEA
Quantity 0–234
Limitation because of 240 Bytes Data block size
(compatible with former PROFIdrive version 3.1.2).
0xEB…0xFF
Reserved
Error Number
Unsigned 16
0x0000…
Error numbers
The more significant byte is reserved.
0x00FF
Generic station description (GSD) file
Please refer GSD file “EATN0EF5.gsd”