215
Appendix A—Parameter ID list
POWERXL SERIES VFD
MN040010EN—June 2018 www.eaton.com
Menu Item
No.
Modbus
Register
PROFIBUS
Parameter Description
Data
Type
Length
(in Bytes)
Display
Format
PNU
PNU
SubIndex
P11.4.3
505
NA
NA
Interval 4 Off Time
BYTE
3
x0
P11.4.4
526
3122
3
Interval 4 From Day
BYTE
1
x0
P11.4.5
527
3123
3
Interval 4 To Day
BYTE
1
x0
P11.4.6
528
3124
3
Interval 4 Channel
BYTE
1
x0
P11.5.1
2491
NA
NA
Interval 5 Setting
BYTE
1
x0
P11.5.2
507
NA
NA
Interval 5 On Time
BYTE
3
x0
P11.5.3
509
NA
NA
Interval 5 Off Time
BYTE
3
x0
P11.5.4
529
3122
4
Interval 5 From Day
BYTE
1
x0
P11.5.5
530
3123
4
Interval 5 To Day
BYTE
1
x0
P11.5.6
531
3124
4
Interval 5 Channel
BYTE
1
x0
P11.6.1
511
3100
0
Timer 1 Duration
DOUBLE
4
x0
P11.6.2
532
3102
0
Timer 1 Channel
BYTE
1
x0
P11.6.3
513
3100
1
Timer 2 Duration
DOUBLE
4
x0
P11.6.4
533
3102
1
Timer 2 Channel
BYTE
1
x0
P11.6.5
515
3100
2
Timer 3 Duration
DOUBLE
4
x0
P11.6.6
534
3102
2
Timer 3 Channel
BYTE
1
x0
P12.1.1
2533
NA
NA
FB Process Data Input 1 Sel
INTEGER
2
x0
P12.1.2
2534
NA
NA
FB Process Data Input 2 Sel
INTEGER
2
x0
P12.1.3
2535
NA
NA
FB Process Data Input 3 Sel
INTEGER
2
x0
P12.1.4
2536
NA
NA
FB Process Data Input 4 Sel
INTEGER
2
x0
P12.1.5
2537
NA
NA
FB Process Data Input 5 Sel
INTEGER
2
x0
P12.1.6
2538
NA
NA
FB Process Data Input 6 Sel
INTEGER
2
x0
P12.1.7
2539
NA
NA
FB Process Data Input 7 Sel
INTEGER
2
x0
P12.1.8
2540
NA
NA
FB Process Data Input 8 Sel
INTEGER
2
x0
P12.2.1
1556
442
0
FB Process Data Output 1 Sel
INTEGER
2
x0
P12.2.2
1557
442
1
FB Process Data Output 2 Sel
INTEGER
2
x0
P12.2.3
1558
442
2
FB Process Data Output 3 Sel
INTEGER
2
x0
P12.2.4
1559
442
3
FB Process Data Output 4 Sel
INTEGER
2
x0
P12.2.5
1560
442
4
FB Process Data Output 5 Sel
INTEGER
2
x0
P12.2.6
1561
442
5
FB Process Data Output 6 Sel
INTEGER
2
x0
P12.2.7
1562
442
6
FB Process Data Output 7 Sel
INTEGER
2
x0
P12.2.8
1563
442
7
FB Process Data Output 8 Sel
INTEGER
2
x0
P12.2.9
2415
NA
NA
Standard Status Word Bit0 Function Select
BYTE
1
x0
P12.2.10
2416
NA
NA
Standard Status Word Bit1 Function Select
BYTE
1
x0
P12.2.11
2417
NA
NA
Standard Status Word Bit2 Function Select
BYTE
1
x0
P12.2.12
2418
NA
NA
Standard Status Word Bit3 Function Select
BYTE
1
x0
P12.2.13
2419
NA
NA
Standard Status Word Bit4 Function Select
BYTE
1
x0
P12.2.14
2420
NA
NA
Standard Status Word Bit5 Function Select
BYTE
1
x0
P12.2.15
2421
NA
NA
Standard Status Word Bit6 Function Select
BYTE
1
x0
P12.2.16
2422
NA
NA
Standard Status Word Bit7 Function Select
BYTE
1
x0
P12.3.1.1
586
3220
0
RS485 Comm Set
BYTE
1
x0
P12.3.2.1
587
3221
0
Slave Address
BYTE
1
x0
P12.3.2.2
584
3222
0
Baud Rate
BYTE
1
x0
P12.3.2.3
585
3224
0
Parity Type
BYTE
1
x0
P12.3.2.4
588
3225
0
Modbus RTU Protocol Status
BYTE
1
x0
P12.3.2.5
593
3290
0
Comm Timeout Modbus RTU
INTEGER
2
x0
P12.3.2.6
2516
NA
NA
Modbus RTU Fault Response
BYTE
1
x0
P12.3.3.1
594
NA
NA
MSTP Baud Rate
BYTE
1
x0
P12.3.3.2
595
NA
NA
MSTP Device Address
BYTE
1
x0
P12.3.3.3
596
NA
NA
MSTP Instance Number
DOUBLE
4
x0
P12.3.3.4
598
NA
NA
MSTP Comm Timeout
INTEGER
2
x0
Table 206. DH1 Parameter ID list, continued
Summary of Contents for PowerXL Series
Page 1: ...Effective June 2018 Supersedes October 2017 Communication manual PowerXL Series VFD...
Page 24: ...xxiv S curit du moteur et de l quipement POWERXL SERIES VFD MN040010EN June 2018 www eaton com...
Page 254: ...230 Hardware speci cation POWERXL SERIES VFD MN040010EN June 2018 www eaton com...
Page 255: ...231 Hardware speci cation POWERXL SERIES VFD MN040010EN June 2018 www eaton com...