189
Appendix A—Parameter ID list
POWERXL SERIES VFD
MN040010EN—June 2018 www.eaton.com
Menu
Item
No.
Modbus
Register
PROFIBUS
EtherNet/IP
DeviceNet
Parameter
Description
Data
Type
Length
(in Bytes)
Display
Format
PNU
PNU
SubIndex
Class Instance Attribute Class Instance Attribute
P10.34
1332
2112
0
160
1
247
170
1
32
PID1 Feedback 1
Source
BYTE
1
x0
P10.35
1333
2172
0
160
1
248
170
1
33
PID1 Feedback 1 Min
INTEGER
2
x100
P10.36
1334
2173
0
160
1
249
170
1
34
PID1 Feedback 1 Max
INTEGER
2
x100
P10.37
1335
2117
0
160
1
250
170
1
35
PID1 Feedback 2
Source
BYTE
1
x0
P10.38
1336
2181
0
160
1
251
170
1
36
PID1 Feedback 2 Min
INTEGER
2
x100
P10.39
1337
2182
0
160
1
252
170
1
37
PID1 Feedback 2 Max
INTEGER
2
x100
P10.40
1338
2800
0
160
1
253
170
1
38
PID1 Feedforward
Func
BYTE
1
x0
P10.41
1339
2801
0
160
1
254
170
1
39
PID1 Feedforward
Gain
INTEGER
2
x10
P10.42
1340
2810
0
160
1
255
170
1
40
PID1 Feedforward 1
Source
BYTE
1
x0
P10.43
1341
2811
0
161
1
1
170
1
41
PID1 Feedforward
1 Min
INTEGER
2
x100
P10.44
1342
2812
0
161
1
2
170
1
42
PID1 Feedforward
1 Max
INTEGER
2
x100
P10.45
1343
2815
0
161
1
3
170
1
43
PID1 Feedforward 2
Source
BYTE
1
x0
P10.46
1344
2816
0
161
1
4
170
1
44
PID1 Feedforward
2 Min
INTEGER
2
x100
P10.47
1345
2817
0
161
1
5
170
1
45
PID1 Feedforward
2 Max
INTEGER
2
x100
P10.48
1352
2830
0
161
1
10
170
1
46
PID1 Set Point 1
Comp Enable
BOOLEAN 1
x0
P10.49
1353
2831
0
161
1
11
170
1
47
PID1 Set Point 1
Comp Max
INTEGER
2
x100
P10.50
1354
2835
0
161
1
12
170
1
48
PID1 Set Point 2
Comp Enable
BOOLEAN 1
x0
P10.51
1355
2836
0
161
1
13
170
1
49
PID1 Set Point 2
Comp Max
INTEGER
2
x100
P10.52
2466
NA
NA
NA
NA
NA
NA
NA
NA
PID1 Wake Up Action
BYTE
1
x0
P10.53
2542
NA
NA
NA
NA
NA
NA
NA
NA
FB PID1 Set Point 1
DOUBLE
4
x100
P10.54
2544
NA
NA
NA
NA
NA
NA
NA
NA
FB PID1 Set Point 2
DOUBLE
4
x100
P10.55
2550
NA
NA
NA
NA
NA
NA
NA
NA
FB PID1 Feedback 1
INTEGER
2
x100
P10.56
2551
NA
NA
NA
NA
NA
NA
NA
NA
FB PID1 Feedback 2
INTEGER
2
x100
P10.57
2554
NA
NA
NA
NA
NA
NA
NA
NA
FB PID1 Feedforward
1
INTEGER
2
x100
P10.58
2555
NA
NA
NA
NA
NA
NA
NA
NA
FB PID1 Feedforward
2
INTEGER
2
x100
P11.1
1356
2100
1
161
1
14
171
1
1
PID2 Control Gain
INTEGER
2
x100
P11.2
1357
2101
1
161
1
15
171
1
2
PID2 Control I Time
INTEGER
2
x100
P11.3
1358
2102
1
161
1
16
171
1
3
PID2 Control D Time
INTEGER
2
x100
P11.4
1359
2870
1
161
1
17
171
1
4
PID2 Process Unit
BYTE
1
x0
P11.5
1360
2871
1
161
1
19
171
1
5
PID2 Process Unit
Min
DOUBLE
4
x100
P11.6
1362
2872
1
161
1
20
171
1
6
PID2 Process Unit
Max
DOUBLE
4
x100
P11.7
1364
2873
1
161
1
18
171
1
7
PID2 Process Unit
Decimal
BYTE
1
x0
P11.8
1365
2850
1
161
1
21
171
1
8
PID2 Error Inversion
BOOLEAN 1
x0
P11.9
1366
2851
1
161
1
22
171
1
9
PID2 Dead Band
DOUBLE
4
x100
P11.10
1368
2852
1
161
1
23
171
1
10
PID2 Dead Band
Delay
INTEGER
2
x100
Table 205. DG1 Parameter ID list, continued
Summary of Contents for PowerXL Series
Page 1: ...Effective June 2018 Supersedes October 2017 Communication manual PowerXL Series VFD...
Page 24: ...xxiv S curit du moteur et de l quipement POWERXL SERIES VFD MN040010EN June 2018 www eaton com...
Page 254: ...230 Hardware speci cation POWERXL SERIES VFD MN040010EN June 2018 www eaton com...
Page 255: ...231 Hardware speci cation POWERXL SERIES VFD MN040010EN June 2018 www eaton com...