219
Appendix A—Parameter ID list
POWERXL SERIES VFD
MN040010EN—June 2018 www.eaton.com
Menu Item
No.
Modbus
Register
PROFIBUS
Parameter Description
Data
Type
Length
(in Bytes)
Display
Format
PNU
PNU
SubIndex
B9.1.3
2136
NA
NA
Protocol Status
BYTE
1
x0
B9.2.1
2137
NA
NA
MAC ID
BYTE
1
x0
B9.2.2
2138
NA
NA
Baud Rate
BYTE
1
x0
B9.2.3
2187
NA
NA
IO Poll Type
BYTE
1
x0
B9.2.4
2212
NA
NA
Dnet Comm Timeout
INTEGER
2
x0
B9.2.5
2519
NA
NA
Comm Card FB Fault Response
BYTE
1
x0
B11.1.1
910
710
2
Board Status
BYTE
1
x0
B11.1.2
1067
NA
NA
Firmware Version
INTEGER
4
x0
B11.1.3
915
550
200
DI1, DI2, DI3
BYTE
1
x0
B11.1.4
914
761
2
DO1, DO2, DO3
BYTE
1
x0
B11.1.5
917
593
200
Thermistor Resistor
DOUBLE
4
x0
B11.1.6
913
753
200
Thermistor State
BYTE
1
x0
B11.2.1
244
461
200
DO1 Function
BYTE
1
x0
B11.2.2
245
461
201
DO2 Function
BYTE
1
x0
B11.2.3
246
461
202
DO3 Function
BYTE
1
x0
B11.2.4
916
343
200
Thermistor Config
BYTE
1
x0
B12.1.1
910
710
2
Board Status
BYTE
1
x0
B12.1.2
1067
NA
NA
Firmware Version
INTEGER
4
x0
B12.1.3
920
560
200
AI1 Value
INTEGER
2
x1000
B12.1.4
923
570
200
AO1 Value
INTEGER
2
x1000
B12.1.5
925
570
201
AO2 Value
INTEGER
2
x1000
B12.2.1
919
NA
NA
AI1 Mode
BYTE
1
x0
B12.2.2
129
260
200
AI1 Signal Range
BYTE
1
x0
B12.2.3
130
264
200
AI1 Custom Min
INTEGER
2
x100
B12.2.4
131
265
200
AI1 Custom Max
INTEGER
2
x100
B12.2.5
128
266
200
AI1 Filter Time
INTEGER
2
x100
B12.2.6
132
267
200
AI1 Signal Invert
BOOLEAN
1
x0
B12.2.7
922
276
200
AO1 Mode
BYTE
1
x0
B12.2.8
275
460
200
AO1 Function
BYTE
1
x0
B12.2.9
276
279
200
AO1 Minimum
BYTE
1
x0
B12.2.10
277
277
200
AO1 Filter Time
INTEGER
2
x100
B12.2.11
278
274
200
AO1 Scale
INTEGER
2
x0
B12.2.12
279
278
200
AO1 Inversion
BOOLEAN
1
x0
B12.2.13
280
275
200
AO1 Offset
INTEGER
2
x100
B12.2.14
924
276
201
AO2 Mode
BYTE
1
x0
B12.2.15
281
460
201
AO2 Function
BYTE
1
x0
B12.2.16
282
279
201
AO2 Minimum
BYTE
1
x0
B12.2.17
283
277
201
AO2 Filter Time
INTEGER
2
x100
B12.2.18
284
274
201
AO2 Scale
INTEGER
2
x0
B12.2.19
285
278
201
AO2 Inversion
BOOLEAN
1
x0
B12.2.20
286
275
201
AO2 Offset
INTEGER
2
x100
B13.1.1
910
710
2
Board Status
BYTE
1
x0
B13.1.2
1067
NA
NA
Firmware Version
INTEGER
4
x0
B13.1.3
926
762
2
RO1, RO2, RO3
BYTE
1
x0
B13.2.1
552
451
200
RO1 Function
BYTE
1
x0
B13.2.2
555
451
201
RO2 Function
BYTE
1
x0
B13.2.3
556
451
202
RO3 Function
BYTE
1
x0
B14.1.1
910
710
2
Board Status
BYTE
1
x0
B14.1.2
1067
NA
NA
Firmware Version
INTEGER
4
x0
B14.1.3
931
757
2
PT100 State
INTEGER
6
x0
B14.1.4
928
NA
NA
PT100 Values
INTEGER
6
x10
Table 206. DH1 Parameter ID list, continued
Summary of Contents for PowerXL Series
Page 1: ...Effective June 2018 Supersedes October 2017 Communication manual PowerXL Series VFD...
Page 24: ...xxiv S curit du moteur et de l quipement POWERXL SERIES VFD MN040010EN June 2018 www eaton com...
Page 254: ...230 Hardware speci cation POWERXL SERIES VFD MN040010EN June 2018 www eaton com...
Page 255: ...231 Hardware speci cation POWERXL SERIES VFD MN040010EN June 2018 www eaton com...