C H A P T E R 2
Eddy Current Brake Installation
Above Ground Model 250i Motorcycle Dynamometer Installation Guide
2-24
3
Verify the eyelets on the load cell are spaced the same as the bar removed earlier.
Adjust the load cell spacing by loosening the lock nut and turning the eyelet.
Figure 2-21: Verify Load Cell Spacing
4
Secure the load cell to the mounting bracket using the two bolts and nuts removed
earlier.
Refer to “Cable Routing” on page 2-28 for more information on routing the load
cell cable.
Refer to “Load Cell Calibration” on page 2-45 for more information on calibrating
the load cell.l
Figure 2-22: Install the Load Cell
distance must be
the same
eyelet
bar
lock nut
load cell cable
load cell