1-9
S P E C I F I C A T I O N S A N D O P E R A T I N G R E Q U I R E M E N T S
Dynamometer Specifications and Requirements
Version 4
Above Ground Model 250i Motorcycle Dynamometer Installation Guide
E
LECTRICAL
R
EQUIREMENTS
The Model 200i/250i dynamometers require a 240V - 30a single-phase electrical
circuit for reliable and precise operation. No other loads should be plugged into this
circuit and this circuit should be independent of the lighting in the dyno room. Before
you plug in your dyno, you or your electrician must refer to
for detailed
information.
E
NVIRONMENTAL
R
EQUIREMENTS
F
IRE
S
UPPRESSION
Always have adequate fire suppression or fire extinguishers in your dyno room.
F
ORKLIFT
R
EQUIREMENTS
You will need to provide equipment capable of lifting a minimum of 1,133.98 kg
(2,500 lbs.) to lift the dyno off the crate and into position in your dyno room. You will
also need a pair of straps capable of supporting the uncrated dyno. Dynojet
recommends using single loop style straps. Using lift straps with bare forks is no
OSHA compliant.
description
specifications
Power Requirements
240v 30 amp single phase circuit
Frequency
50 or 60 Hz
Voltage
normal
240 VAC
min./max
215 VAC/245 VAC except Japan 195 VAC/245 VAC
Current
30 amps
Power Consumption
7200 watts
Power Cord
P/N 76950401
length
3.048 m (10 ft.)
end
twist-lock plug or three-pin IEC plug
wall receptacle (included with dyno)
twist-lock four wire grounded 30A NEMA L14-30 or
three-pin IEC grounded 30A
Full Load Amperage (FLA)
30A
description
specifications
Temperature
operating min./max
10°C/50°C (50°F/122°F)
storage min./max
0°C/60°C (32°F/140°F)
Humidity
0 to 95% non-condensing