2-45
D Y N O I N S T A L L A T I O N
Load Cell Calibration
Version 4
Above Ground Model 250i Motorcycle Dynamometer Installation Guide
LOAD CELL CALIBRATION
The load cell is an optional accessory. Before proceeding, make sure all cables have
been routed and the covers have been installed. This section provides instructions for
calibrating the load cell. Follow the directions on the screen exactly. Failure to
perform the directions accurately will result in improper torque values.
You will need the following parts:
1
Verify the dyno is connected to power. Refer to “Main Dyno Power” on page 1-3.
2
Double-click the Power Core program icon.
3
Click
Dyno Control
from the Application Launcher.
4
Verify you are connected to the DynoWare RT main module.
Note:
For more information on connecting to the DynoWare RT, refer to the
Power Core Quick Start Guide or the Power Core Online Help.
5
From the Configuration ribbon, click
Load Cell Calibration
.
6
Remove the calibration arm and mass if it is installed.
7
Release the dyno brake. Make sure the drums are free to rotate.
Note:
There should not be anything resting on the eddy current brake or the dyno
drum during this procedure.
8
Click
Next
to zero the connected torque cell.
Figure 2-41: Zero Calibration Window
part
description
part
description
weight, 25 pounds (4)
P/N 35430899
calibration arm assembly
P/N 61319001