GBK60027 DX-SLM Installation Manual Issue 5
DX System
Status LED
Flash Code
SLM Status
LED Flash
Code
Likely Cause of Fault and Possible Action
10
10
CANH Fault
Cause:
1. An invalid voltage has been
detected on the DXBUS CANH line.
2. Communication is not possible using
the CANH wire.
3. Hazard lights were already turned on
when the DX System was turned on.
Action:
•
Check the continuity of the DXBUS
cable.
•
Check for shorts between DXBUS pins.
An open or short circuit on another DX
module can cause this fault.
•
If the Hazard Lights were already
switched on when the DX System was
turned on, Flash Code 10 and Limp
Mode (slow driving) may result.
To clear this fault, turn the Hazard Lights
off, then turn the DX System off then on
again.
11
11
Stall Timeout Fault
Cause:
The servo motor current has been at or
close to current limit for longer than the
Stall Timeout parameter value.
Action:
•
Turn the DX System off then on again.
8.3
Wizard Diagnostics
Wizard is the preferred diagnostics tool in the workshop environment, providing a full
fault history and showing any current faults.
If after analysing the data, the condition cannot be diagnosed, it is possible to print,
save, or e-mail a Status Report for further analysis or distribution to a service centre.
Page 46
M
T