GBK60027 DX-SLM Installation Manual Issue 5
DX System
Status LED
Flash Code
SLM Status
LED Flash
Code
Likely Cause of Fault and Possible Action
2
4
Lighting Fault
Cause:
1. A fault is detected in the lighting
circuits.
2. Indicator lights are flashing faster
than normal.
3. LED lamps have been fitted to the
indicator lights but the Lighting
Current Test parameter has not
been set to "Disable".
Action:
•
Check the lighting circuitry for shorts
and open circuits.
•
Check side and indicator bulbs.
2
5
Clutch Released
Cause:
The clutch switch is or has been in the
released position.
Action:
•
Re-engage the clutch if necessary
and turn the DX System off then on.
•
Check the servo motor connector
and wiring.
•
Check the operation of the clutch
switch.
7
7
Low Battery Voltage Fault
Cause:
The battery voltage has fallen below
17 V.
Action:
•
Check battery connections and
terminals.
•
Check fuses have not blown or circuit
breakers tripped.
•
Replace battery if worn out.
9
9
CANL Fault
Cause:
1. An invalid voltage has been
detected on the DX BUS CANL line.
2. Communication is not possible using
the CANL wire.
Action:
•
Check the continuity of the DX BUS
cable.
•
Check for shorts between DX BUS pins.
An open or short circuit on another DX
module can cause this fault.
Page 45
M