GBK60027 DX-SLM Installation Manual Issue 5
DX System
Status LED
Flash Code
SLM Status
LED Flash
Code
Likely Cause of Fault and Possible Action
1
1
Module Fault
Cause:
Connections between DX Modules may
be faulty, or there may be an internal
fault in the SLM.
Action:
•
Check DX BUS connections and
replace where necessary.
•
Replace SLM.
•
Consult an approved Dynamic
Service Agent
1
2
Motor Fault
Cause:
A servo motor fault has been detected.
Action:
•
Check wiring to motor.
•
Check servo motor for a short or open
circuit.
2
3
Steering Fault*
Cause:
Connections between DX Modules may
be faulty, or there may be an internal
fault in the SLM.
Action:
•
Check the Pot Shaft is not slipping, or
the Pot body turning.
•
Check the Pot for short and open
circuits between pins.
•
Ensure that the clutch is engaged and
not slipping.
•
Ensure that there is no excessive load
on the steering system.
•
Check the servo motor connector
and wiring
*Note:
If the Steering Fault only occurs when large steering movements are
requested, the SLM‘s motor speed parameter may need to be recalibrated
using an HHP.
Page 44
M
T