GBK60027 DX-SLM Installation Manual Issue 5
7.3.3
Steering Position Feedback Pot Parameters
7.3.3.1
Left Lock
Parameter
Possible Values Default
HHP Lite Std Adv
Left Lock
5 - 95 %
25 %
-
-
The ratio of the Position Sense Pot Wiper voltage to the full pot voltage when the
steering wheels are moved as far left as is mechanically possible.
A physical limitation calibrated using the HHP - refer to section 7.4.
7.3.3.2
Right Lock
Parameter
Possible Values Default
HHP Lite Std Adv
Right Lock
5 - 95 %
75 %
-
-
The ratio of the Position Sense Pot Wiper voltage to the full pot voltage when the
steering wheels are moved as far right as is mechanically possible.
A physical limitation calibrated using the HHP - refer to section 7.4.
Note:
The Left and Right Lock parameters must not both be above nor both be
below 50%. Typically, one will be around 25% and the other around 75%, so
that the total will be around 100%.
Position
Sense
Pot
0 V
100%
0%
SP+
Max Pot End V
Min Pot End V
Right Lock
Left Lock
Pot Voltage Tolerance
Lock Margin
Lock Margin
Actual Lock Limits
Physical Pot Limits
Page 35