GBK60027 DX-SLM Installation Manual Issue 5
7.3.4
Joystick Restrictor Plate Table
7.3.4.1
Restrict Speed
Parameter
Possible Values Default
HHP Lite Std Adv
Restrict Forward Speed 25 %
60 - 100 %
90 %
-
-
Restrict Forward Speed 50 %
40 - 100 %
60 %
-
-
Restrict Forward Speed 75 %
20 - 100 %
30 %
-
-
Restrict Forward Speed 100 %
0 - 100 %
5 %
-
-
Restrict Reverse Speed 25 %
60 - 100 %
75 %
-
-
Restrict Reverse Speed 50 %
40 - 100 %
53 %
-
-
Restrict Reverse Speed 75 %
20 - 100 %
30 %
-
-
Restrict Reverse Speed 100 %
0 - 100 %
5 %
-
-
The maximum forward and reverse speeds for four non-zero lock positions: 25, 50, 75,
and 100 % turning lock.
The physical restrictor plate fitted to the DX Remote is calibrated with these
parameters, using the HHP.
If the DX Remote is replaced, these parameters must be recalibrated.
Plate parameters are grouped and calibrated in one operation of the HHP.
7.3.5
Miscellaneous Parameters
7.3.5.1
Speed Scalar
Parameter
Possible Values Default
HHP Lite Std Adv
Speed Scalar
0 - 100 %
0 %
-
-
-
The Speed Scalar value scales the speed so that 100% speed occurs closer to neutral.
If the Speed Scalar is set to 0 %, the joystick must be deflected to point ‘c’ to achieve
100 % forward or reverse speed.
Page 37
M
T