Wire Sizes
The minimum wire sizes that must be used are:
Function
Wire Size (minimum)
Terminal Part*
DX BUS -
1.0 mm²
FC116N2
Side Lights -
0.5 mm²
FC120N2
Left Indicator -
0.5 mm²
FC120N2
Right Indicator -
0.5 mm²
FC120N2
Alternative Li
1.0 mm²
FC116N2
Hazard In
0.5 mm²
FC120N2
Hazard Out
0.5 mm²
FC120N2
Battery -
1.0 mm² motors < 10 A
2.0 mm² motors ≥ 10 A
FC116N2
FC114N2
Steering Power +
1.0 mm² motors < 10 A
2.0 mm² motors ≥ 10 A
FC116N2
FC114N2
DX BUS +
1.0 mm²
FC116N2
Li
1.0 mm²
FC116N2
* Positronic Industries Ltd
5.4.3
Power Supply from the DX BUS
The DX BUS is suitable for powering low speed servomotors and lighting, where the DX
System current requirement is less than the 12 A DX BUS rating.
To power the lighting and servomotor from the DX BUS, links must be inserted to short
the DX BUS - pin to the Battery - pin, and the DX BUS + pin to the Steering Power and
Li pins.