Speci
fi
cations
118
Model name
DC-516
Power consumption
In operation
Standby
Current
Power
Current
Power
100 V
4.7 A
380 W
0.81 A
67 W
115 V
4.1 A
380 W
0.72 A
67 W
230 V
2.0 A
370 W
0.46 A
67 W
Weight Net
Gross
100 V
126 kg
164 kg
115 V
140 kg
178 kg
115 V (PRO)
165 kg
205 kg
230 V
134 kg
173 kg
230 V AP
169 kg
210 kg
Dimension
In use: 1540 (W) × 795 (D) × 1085 (H) mm
In use (Max): 2125 (W) × 795 (D) × 1085 (H) mm
Stored: 1060 (W) × 795 (D) × 1160 (H) mm
Required max. dimension: 2125 (W) × 1375 (D) × 1510 (H) mm
Packed: 1165 (W) × 920 (D) × 1370 (H) mm
Operating temperature/
humidity
10°C–30°C, 40%RH
−
70%RH (No condensation)
Storing temperature/
humidity
0°C–50°C, 10%RH
−
80%RH (No condensation)
Noise level
In operation: less than 80 dB
Safety standard
UL, CE (low voltage directive, machinery directive), VCCI, FCC
Operating altitude
Max 1000 mm a.s.l.
Overvoltage category
Category II according to IEC60664-1
Environmental pollution
Pollution degree: degree 3 according to IEC60664-1
●
The speci
fi
cations are subject to change without prior notice.
Document Curl
Due to the automated slitter function design, the document path of the DC-516 is sensitive to
document curl.
If document curl is causing document jams, the following are suggestions for remedying the
problem:
1. Adjust the printing devices de-curler (if available).
2. Manually de-curl the stock before loading in the feed tray.
3. Turn the document over (reprogramming the job may be necessary).