57
Default Batch Sequence
Line
Number
Command
Instruction
Description
00
CLR ALL OUTPUTS
All Outputs are non-active.
01
WAIT UNTIL STABLE
Wait until indicator is stable.
02
PUSH BUTTON ZERO
Push button Zero.
03
SET OUTPUT 1
Output 1 is active.
04
WAIT FOR SETPOINT 1
Wait until setpoint 1 is active.
05
CLR OUTPUT 1
Output 1 is non-active.
06
WAIT UNTIL STABLE
Wait until indicator is stable.
07
PUSH BUTTON TARE
Push button Tare.
08
SET OUTPUT 2
Output 2 is active.
09
WAIT FOR SETPOINT 2
Wait until setpoint 2 is active.
10
CLR OUTPUT 2
Output 2 is non-active.
11
WAIT UNTIL STABLE
Wait until indicator is stable.
12
PUSH BUTTON TARE
Push button Tare.
13
SET OUTPUT 3
Output 3 is active.
14
WAIT FOR SETPOINT 3
Wait until setpoint 3 is active.
15
CLR OUTPUT 3
Output 3 is non-active.
16
WAIT UNTIL STABLE
Wait until indicator is stable.
17
PUSH BUTTON TARE
Push button Tare.
18
SET OUTPUT 4
Output 4 is active.
19
WAIT FOR SETPOINT 4
Wait until setpoint 4 is active.
20
CLR OUTPUT 4
Output 4 is non-active.
21
WAIT UNTIL STABLE
Wait until indicator is stable.
22
GROSS
Indicator is set for gross mode.
23
WAIT 00
Pause until START button is pressed.
24
GLOBAL REPEAT 00
Global repeat back to line 00.
25
END OF BATCH
End of batching sequence.
Batch Configuration
Operation Mode Menu (
oP
)
Parameter:
oP
=
bAt
or
bAn
Setpoint Operation Menu (
S.o.
)
Parameter:
SP1
=
HA
,
SP2
=
HA
,
SP3
=
HA
,
SP4
=
HA
Test Mode Menu (XXXXXX)
Operation Menu (
out 1
,
out 2
,
out 3
,
out 4
)
Parameter:
oI
=
BAt
(all four outputs)