127
Bluetooth Option
Doran Scale’s Bluetooth option (EXOPT202) is a Class 1,
Bluetooth
Version 2.0. The
Bluetooth option consists of a module that is factory configured for auto-connection,
discoverable, and slave mode. Up to 7-slaves (scales) can be connected to one master
(computer) at a time. The Bluetooth option does not require an external antenna for
communication. Once paired, the Bluetooth module will function as a straight RS232
serial cable. Each Bluetooth module has an individual 12-digit address i.e.
“008098E6F287” and description field “Ezurio blu2i” for identification purposes.
Computer Setup
To connect the scale’s Bluetooth module with your computer, the computer will need to
have a Bluetooth device installed. Some computers may or may not have a Bluetooth
option. If there is no existing Bluetooth device, a Bluetooth USB dongle will need to be
installed. Follow the instructions included with the Bluetooth dongle software to setup the
computer.
Bluetooth USB Dongle
Since Bluetooth software drivers and hardware vary among manufacturers, it is
recommended to use a Cirago BTA-6210 USB Bluetooth dongle, Doran part number
EXOPT204.
Scale Setup
To setup the scale’s software for the Bluetooth module, the Handshaking Setup Menu
“
HS
” should be set for Bluetooth “
bt
”.
Jumper Settings
JU30 and JU31 located on the scale’s main board must have jumper shunts on PORT1
side. See Fig. 12 for Jumper location.
Pairing Devices (Scale)
The scale’s Bluetooth module must be paired with your computer to communicate
properly. Turn on the scale with the Bluetooth option installed. Be sure to have the scale
near the computer to prevent any interference with communication while configuring the
Bluetooth module. Wait 30 seconds after the scale is powered up to allow the scale’s
Bluetooth module to become connectable and discoverable.
PIN Code
The Scale’s Bluetooth module is configured with an enable authentication, which
requires a PIN code for incoming and outgoing connections. When the computer
prompts for a PIN code, enter in “12345” to accept pairing between master (computer)
and slave (scale) devices.
Dropping Connections
When power is removed from either the scale or the computer, the Bluetooth connection
(Pairing) between the two is disconnected.