54
Batch Commands (2200B)
Command
Instruction
Batching command list (2200B model only)
Specifies command to be executed at each step up to 100 steps. See
Batch Command Explained for a detailed explanation of each
command.
NOP
Causes no operation, execution simply passes to the next instruction in
the list (useful for allowing insertion of a command in the future).
SET ALL OUTPUTS
All Outputs 1 to 8 are active. NOTE: All the output logic parameters
"
o1
" through "
o8
" must be set to batch "
BAT
".
SET
OUTPUT 1-8
Output 1 - 8 becomes active. NOTE: The output logic parameter "
o1
" to
"
o8
" must be set to batch "
BAT
".
CLR ALL
OUTPUTS
All Outputs 1 to 8 are non-active. NOTE: All the output logic
parameters "
o1
" through "
o8
" must be set to batch "
BAT
".
CLR
OUTPUT 0-8
Output 1- 8 becomes non-active. NOTE: The output logic parameter
"
o1
" to "
o8
" must be set to batch "
BAT
".
WAIT 00-99
Causes the batch sequence to wait for a specified amount of time. 00
command waits until START pb to be pressed, 01-99 waits in seconds.
PUSH BUTTON
TARE
Causes a push-button TARE, only if the indicator is stable. A "
TArE
"
message will be displayed if tare operation was successful. Press
START button to bypass this command.
PUSH BUTTON
ZERO
Causes a push-button ZERO, only if the indicator is stable. A "
2ERo
"
message will be displayed if zero operation was successful. Press
START button to bypass this command.
PRINT TO PORT1
Send a print string to Port 1, only if the indicator is stable. Displayed
weight is added to Accumulator and the Counter is incremented.
PRINT TO PORT2
Send a print string to Port 2, only if the indicator is stable. The
Accumulator and Counter are not effected.
PRINT TO BOTH
PORTS
Send a print string to Port 1 and Port 2, only if the indicator is stable.
Displayed weight is added to Accumulator and the Counter is
incremented.
PRINT USER
STRING 1-4
TO PORT 1
Transmits User print string 1-4 out Port 1. The Accumulator and
Counter are not effected.
PRINT USER
STRING 1-4
TO PORT 2
Transmits User print string 1-4 out Port 2. The Accumulator and
Counter are not effected.
NET
Places the indicator in the NET display mode only if a tare weight is
stored.
GROSS
Places the indicator in the GROSS display mode.
WAIT UNTIL
STABLE
Causes the batching sequence to wait until the indicator is stable.
Press START button to bypass this command.
GLOBAL REPEAT
00-99
Causes a global repeat back to line 1, for the number of times
specified. 00 = loop indefinitely. A "
Gl Rep
" message will be displayed
if the operation was successful.
START OF LOCAL
REPEAT
Start location of local repeat. Must be placed before LOCAL REPEAT
command.