56
ACTIVE
JUMP TO LINE IF
DIN1 ACTIVE
Causes the indicator to jump to a selected line when DIN 1 is active, if
not active, will continue to the next instruction in the list. Press START
button to bypass this command. Note: Remote Switch 1 parameter "
r1
"
must be set for input 1 "
in1
".
JUMP TO LINE IF
DIN2 ACTIVE
Causes the indicator to jump to a selected line when DIN 2 is active, if
not active, will continue to the next instruction in the list. Press START
button to bypass this command. Note: Remote Switch 2 parameter "
r2
"
must be set for input 2 "
in2
".
WAIT FOR
CURRENT
LEARNING
PREACT
SAMPLE
If the current Preact mode menu (
PA1 - PA8
) is set for learn mode
(
LEn
), the batch sequence waits for a stable weight sample to calculate
the current Learning Preact value. Press the START button to bypass
this command.
WAIT FOR
LEARNING
PREACT 1-8
SAMPLE
If the Preact 1 - 8 mode menu (
PA1 - PA8
) is set for learn mode (
LEn
),
the batch sequence waits for a stable weight sample to calculate the
Learning Preact value. Press the START button to bypass this
command.
CLEAR CURRENT
LEARNING
PREACT
Sets Current Learning Preact value to zero. A "
CLr LPr
" message will
be displayed if the operation was successful.
CLEAR LEARNING
PREACT 1-8
Sets Learning Preact 1-8 value to zero. A "
CLr LPr
" message will be
displayed if the operation was successful.
LOAD CURRENT
LEARNING
PREACT
Loads Current fixed Preact value into Current Learning Preact. A "
Ld
LPr
" message will be displayed if the operation was successful.
LOAD LEARNING
PREACT 1-8
Loads fixed Preact 1-8 value into Learning Preact 1-8. A "
Ld LPr
"
message will be displayed if the operation was successful.
WAIT FOR ENTRY
OF USER DELAY
Waits for User Delay entry, 0000-9999 in seconds, 0000 waits for
START pb to be pressed. Press START button to bypass this
command and enter previous stored value.
USER DELAY
WAIT 0000-9999
Causes a pause for a specified amount of time per User Delay Entry.
0000 waits for START pb to be pressed, 0001-9999 in seconds.
END OF BATCH
End of the batching sequence. Place at last line of Batch sequence.
Summary of Contents for 2200 Series
Page 2: ...1 ...
Page 11: ...10 Scale Operation Fig 1 Model 2200 Front Panel Layout Fig 2 Model 2200B Front Panel Layout ...
Page 118: ...117 ...
Page 127: ...126 Fig 37 Mounting Dimensions ...
Page 136: ...135 ...